Log entry time 22:08:11 on October 18, 2009
Entry number 295562
keyword=End_of_Parity_Run_13385__CODA_Config=Happex
************************************************
Run Number: 13385
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production.,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 13385 at Sun Oct 18 22:08:00 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20498
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 186
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.81
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.756
Gun2: PC (PITA) NEG : 5.944
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 902.479
Photodiode on table : 402.542
Laser X position on QPD 1 : 155.005
Laser Y position on QPD 1 : 487.43
Laser X position on QPD 2 : -24.0384
Laser Y position on QPD 2 : -598.046
QPD 1 sum : -1.87756
QPD 2 sum : -1.26961
Position set point for adjustable
mirror 1 (either x or y) : -275[c]
Position set point for adjustable
mirror 2 (either x or y) : 1790[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2223
Polarisation in cavity : RIGHT
Reflection photodiode : 0.396142
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.137337
Fast locking signal sent to laser : 2.67167
Calculated polarisation in cavity : 97.9564
Photodiode 1 after Wollaston prism : 70.5971
Photodiode 2 after Wollaston prism : 0.728805
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1590.2
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.29
Left Arm Q1 momentum : 3.14129
Left Arm Q1 gauss meter : -0.19931
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.62
Left Arm Q2 momentum : 3.14124
Left Arm Q2 gauss meter : 0.71
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.51
Left Arm D1 momentum : 3.1416
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.64
Left Arm Q3 momentum : 3.14138
Left Arm Q3 gauss meter : -0.63076
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.01
Right Arm Q1 momentum : 3.14132
Right Arm Q1 gauss meter : -0.05861
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.71
Right Arm Q2 momentum : 3.14083
Right Arm Q2 gauss meter : 0.7059
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.79
Right Arm D1 momentum : 3.14153
Right Arm D1 NMR : 1.16579
Right Arm Q3 power supply current : 1249.91
Right Arm Q3 momentum : 3.1412
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.80664
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : 0.000976562
Right Arm Bottom VDC voltage : -0.0107422
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 96.7083
Current on Unser monitor : 89.9447
Current on Upstream bcm : 94.2609
Current on Downstream bcm : 99.1556
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 104.26
Tiefenbach Hall A energy : 3482.79
Tiefenbach Hall C energy : 2344.09
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.786153
IPM1C12.YPOS : 0.118956
IPM1H04A.XPOS : -0.342839
IPM1H04A.YPOS : 1.6159
IPM1H04B.XPOS : -1.29475
IPM1H04B.YPOS : 1.98826
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.740978
Survey Y offset bpm12 : 0.118956
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.620166
HacL_HPE1313A:0_Ch58 : -0.213379
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.00830078
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.00576172
HacR_HPE1313A:0_Ch58 : -0.627441
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.961914
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 71.5
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.92
pressure fill target H2 : 26.4195
pressure fill bottle H2 : 26.6011
pressure ballast H2 : 26.067
pressure exhaust H2 : 26.0563
cryogen input temp : 13.9
crogen return flow : 25.1178
JT valve setting : 56.4453
-----------------------------------------