User name apar
Log entry time 09:40:16 on October 19, 2009
Entry number 295670
keyword=Start_Parity_Run_13399__CODA_Config=Happex_Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production.,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 13399 at Mon Oct 19 09:40:09 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20513
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 174
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 5.61
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.625
Gun2: PC (PITA) NEG : 6.075
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01465
Pockels Cell Voltage NEG : 1.82906
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 0.146513
Photodiode on table : 393.071
Laser X position on QPD 1 : 158.074
Laser Y position on QPD 1 : 483.977
Laser X position on QPD 2 : -23.5804
Laser Y position on QPD 2 : -588.098
QPD 1 sum : -1.86047
QPD 2 sum : -1.24886
Position set point for adjustable
mirror 1 (either x or y) : -275[c]
Position set point for adjustable
mirror 2 (either x or y) : 1790[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1376
Polarisation in cavity : LEFT
Reflection photodiode : 0.869804
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 5.54294
Calculated polarisation in cavity : 15.6072
Photodiode 1 after Wollaston prism : 0.00669344
Photodiode 2 after Wollaston prism : 0.00500536
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1590.2
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.24
Left Arm Q1 momentum : 3.14122
Left Arm Q1 gauss meter : -0.19932
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.63
Left Arm Q2 momentum : 3.14126
Left Arm Q2 gauss meter : 0.71
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.52
Left Arm D1 momentum : 3.1416
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.64
Left Arm Q3 momentum : 3.14139
Left Arm Q3 gauss meter : -0.63077
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.07
Right Arm Q1 momentum : 3.14132
Right Arm Q1 gauss meter : -0.05862
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.72
Right Arm Q2 momentum : 3.14086
Right Arm Q2 gauss meter : 0.7061
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.83
Right Arm D1 momentum : 3.14158
Right Arm D1 NMR : 1.1658
Right Arm Q3 power supply current : 1249.91
Right Arm Q3 momentum : 3.14121
Right Arm Q3 gauss meter : 0.5592
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : 0.000488281
Right Arm Bottom VDC voltage : -0.0107422
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 97.1233
Current on Unser monitor : 88.9038
Current on Upstream bcm : 94.6671
Current on Downstream bcm : 99.2742
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 104.886
Tiefenbach Hall A energy : 3482.86
Tiefenbach Hall C energy : 2344.1
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.677719
IPM1C12.YPOS : 0.0940166
IPM1H04A.XPOS : -0.377725
IPM1H04A.YPOS : 1.75055
IPM1H04B.XPOS : -1.29955
IPM1H04B.YPOS : 2.1062
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.707201
Survey Y offset bpm12 : 0.0803099
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.620166
HacL_HPE1313A:0_Ch58 : -0.213379
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.0078125
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.00522461
HacR_HPE1313A:0_Ch58 : -0.627441
HacR_HPE1313A:0_Ch55 : 22.5098
HacR_HPE1313A:0_Ch54 : -0.961426
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72.5
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19
temperature loop 3-3 : 0.92
pressure fill target H2 : 26.3371
pressure fill bottle H2 : 26.5324
pressure ballast H2 : 25.7771
pressure exhaust H2 : 25.9922
cryogen input temp : 13.9
crogen return flow : 25.2254
JT valve setting : 56.6406
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13399 -d '2009-10-19 09:40:07' -t 17740748 -s OUT