    User name K. Grimm

    Log entry time 16:12:16 on October20,2009

    Entry number 295860

    keyword=K. Grimm

    SL: Klaus Grimm
    TO: Chun-Min Jen
    3rd:ZAFAR AHMED


    Summary
    =======

    Smooth production runs at 97uA

    run OK pairs (k) IHWP
    13428 38.3 OUT
    13429 46.4 OUT
    13430 46.4 OUT total OK pairs : 1012.7k
    -----------------------------------
    13433 41.5 IN
    13434 42.4
    13435 22.1 (beam off at the end)

    Special runs
    134232 Dedicated run at 50uA for Happex detector linearity tests performed by Rupes


    Pedestal runs (no beam)
    13436
    13437


    Corrupted runs (CODA crash, missing root files)
    13426
    13427

    Details
    =======

    Shift starts with Happex run 13426 at 97uA and IHWP OUT, slug 27

    08:08 Compton GSO HV trips. Turned HV on (was set to -1800V from previous shift)
    08:30 Compton run 20540 crashed, coda restart
    08:40 start compton run 20451
    08:42 Could not prompt runs 13426 and 13427
    08:45 Runbird was complaining about missing analyser. Caused by a stalled Happex CODA.
    Zafar killed coda and did a "startcoda".
    08:49 Start Happex run 13428
    09:15 Started Coda on left arm
    09:24 Spot++ run 25099, raster size on target: 6.5 x 5 mm
    09:41 Computer Center called in and is asking for ~5min downtime for updating webservers. So during the down time
    we would not be able to make any log entries (manual+automatic). A good time would be during beam studies or
    other schedules downtimes but nothing seems to be scheduled for the day shift. Since we have production runs
    I urged CC to call the run coordinator.
    09:45 Starting prompt analysis which apparently crashed during this morning.
    09:46 Start Happex run 13429
    10:32 Start Compton run 20542
    11:50 Changed IHWP to IN, starting slug 28
    11:52 Start Happex run 13432. Dedicated run at 50uA for Happex detector linearity tests
    performed by Rupesh
    12:14 Start Happex run 13433
    13:07 Compton GSO HV trip.
    13:11 Start Happex run 13434
    14:08 Start Happex run 13435
    14:29 Start Compton run 20545
    14:45 After some beam trips beam is off now
    14:55 MCC: A magnet in south linac is down and its power supply must be replaced. There will be no beam for ~30 min.
    15:06 Start Happex run 13436: dedicated pedestal run (beam off)
    15:47 Start Happex run 13437: dedicated pedestal run (beam off)
    16:08 Resuming beam at 98uA