Log entry time 18:22:49 on October 20, 2009
Entry number 295877
keyword=End_of_Parity_Run_13440__CODA_Config=Happex
************************************************
Run Number: 13440
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
************************************************
End-of-Parity-run EPICS data for Run Number 13440 at Tue Oct 20 18:22:39 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20546
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 186
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.89
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.757
Gun2: PC (PITA) NEG : 5.943
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99267
Pockels Cell Voltage NEG : 1.83394
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr752mW
Calculated power in cavity : 828.194
Photodiode on table : 390.329
Laser X position on QPD 1 : 155.809
Laser Y position on QPD 1 : 470.687
Laser X position on QPD 2 : -19.2401
Laser Y position on QPD 2 : -580.331
QPD 1 sum : -2.09608
QPD 2 sum : -1.36361
Position set point for adjustable
mirror 1 (either x or y) : 30[c]
Position set point for adjustable
mirror 2 (either x or y) : 2260[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2750
Polarisation in cavity : LEFT
Reflection photodiode : 0.379051
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.624428
Fast locking signal sent to laser : 1.58396
Calculated polarisation in cavity : 98.1328
Photodiode 1 after Wollaston prism : 0.610602
Photodiode 2 after Wollaston prism : 64.7908
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1590.2
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 14.001
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.13
Left Arm Q1 momentum : 3.14115
Left Arm Q1 gauss meter : -0.19928
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1353.1
Left Arm Q2 momentum : 3.14237
Left Arm Q2 gauss meter : 0.7102
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.5
Left Arm D1 momentum : 3.14158
Left Arm D1 NMR : 1.16338
Left Arm Q3 power supply current : 1250.67
Left Arm Q3 momentum : 3.14145
Left Arm Q3 gauss meter : -0.63079
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.07
Right Arm Q1 momentum : 3.14132
Right Arm Q1 gauss meter : -0.05861
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1351.75
Right Arm Q2 momentum : 3.14093
Right Arm Q2 gauss meter : 0.7061
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.88
Right Arm D1 momentum : 3.14149
Right Arm D1 NMR : 1.16577
Right Arm Q3 power supply current : 1249.94
Right Arm Q3 momentum : 3.14128
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.95312
Right Arm Bottom VDC Current : -1.46484
Left Arm Top VDC voltage : 0.0175781
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : 0.000488281
Right Arm Bottom VDC voltage : -0.00927734
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 96.6411
Current on Unser monitor : 89.7891
Current on Upstream bcm : 94.3583
Current on Downstream bcm : 98.9239
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 104.838
Tiefenbach Hall A energy : 3482.91
Tiefenbach Hall C energy : 2344.07
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.627863
IPM1C12.YPOS : 0.0885192
IPM1H04A.XPOS : -0.354363
IPM1H04A.YPOS : 1.78885
IPM1H04B.XPOS : -1.31015
IPM1H04B.YPOS : 2.15141
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.599387
Survey Y offset bpm12 : 0.0806483
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.620264
HacL_HPE1313A:0_Ch58 : -0.212891
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.00634766
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.00517578
HacR_HPE1313A:0_Ch58 : -0.627441
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.958496
Right Arm Angle Floor Angle : 14
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 14.001
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 72.5
Encoder position : 17740748
temperature loop 3-1 : 19
temperature loop 3-2 : 19.01
temperature loop 3-3 : 0.92
pressure fill target H2 : 27.1778
pressure fill bottle H2 : 27.2374
pressure ballast H2 : 26.6178
pressure exhaust H2 : 26.9306
cryogen input temp : 13
crogen return flow : 24.5049
JT valve setting : 52.6367
-----------------------------------------