    User name apar

    Log entry time 01:13:09 on October 21, 2009

    Entry number 295909

    keyword=Start_Parity_Run_13448__CODA_Config=HapSimple_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=det linearity test, left arm: baseline outside, diff inside, right arm: both LEDs inside,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 13448 at Wed Oct 21 01:10:06 EDT 2009
    CODA Configuration: HapSimple
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       :  compton:RUN --- Invalid channel name
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.88
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.753
    Gun2: PC (PITA) NEG                      : 5.947
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00733
    Pockels Cell Voltage NEG                 : 1.83883
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              :  COMPTON_LASERP_si --- Invalid channel name
    Calculated power in cavity               :  COMPTON_PW1PCAV_ca --- Invalid channel name
    Photodiode on table                      :  COMPTON_PW2PCAV_ca --- Invalid channel name
    Laser X position on QPD 1                :  COMPTON_Y1SS_ca --- Invalid channel name
    Laser Y position on QPD 1                :  COMPTON_X1SS_ca --- Invalid channel name
    Laser X position on QPD 2                :  COMPTON_Y2SS_ca --- Invalid channel name
    Laser Y position on QPD 2                :  COMPTON_X2SS_ca --- Invalid channel name
    QPD 1 sum                                :  COMPTON_XYSUM1_ca --- Invalid channel name
    QPD 2 sum                                :  COMPTON_XYSUM2_ca --- Invalid channel name
    Position set point for adjustable 
                   mirror 1 (either x or y)  :  COMPTON_POS1_si --- Invalid channel name
    Position set point for adjustable 
                   mirror 2 (either x or y)  :  COMPTON_POS3_si --- Invalid channel name
    Laser minimum temperature (35.8)         :  COMPTON_LASERT_MIN --- Invalid channel name
    Laser temperature set point              :  COMPTON_LASERT_si --- Invalid channel name
    Polarisation in cavity                   :  COMPTON_SU_POLAR_mo --- Invalid channel name
    Reflection photodiode                    :  COMPTON_SERVO_PDRai --- Invalid channel name
    Gain of locking servo                    :  COMPTON_SERVO_GAINao --- Invalid channel name
    Tracking level (V) of locking servo      :  COMPTON_SERVO_SEUILao --- Invalid channel name
    Slow locking signal sent to laser        :  COMPTON_SERVO_SLOWai --- Invalid channel name
    Fast locking signal sent to laser        :  COMPTON_SERVO_FASTai --- Invalid channel name
    Calculated polarisation in cavity        :  COMPTON_CAVPOLAR_ca --- Invalid channel name
    Photodiode 1 after Wollaston prism       :  COMPTON_PW1R_S1_ca --- Invalid channel name
    Photodiode 2 after Wollaston prism       :  COMPTON_PW1R_S2_ca --- Invalid channel name
    Step size for RHWP scan                  :  COMPTON_PVAL_Y_ao --- Invalid channel name
    Laser temp slow ramp (1 = on)            :  COMPTON_CAVSLOW_bo --- Invalid channel name
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         :  COMPTON_CAVPLUSOFT_ca.B --- Invalid channel name
    Speed of laser temp slow ramp down       :  COMPTON_CAVMOINSOFT_ca.B --- Invalid channel name
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     :  MF7b1461_2ch9property.F --- Invalid channel name
    S0 Front End, HV - Left Slot7 Card2 Ch9    :  MF7b1461_2ch1property.F --- Invalid channel name
    S0 Back End, HV - Left Slot7 Card2 Ch9  :  MF7b1461_2ch7property.F --- Invalid channel name
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.0534066
    Left Arm Q1 momentum                     : 0.000222177
    Left Arm Q1 gauss meter                  : 0.0002948
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0159299
    Left Arm Q2 momentum                     : 0.00362481
    Left Arm Q2 gauss meter                  : 0.0009761
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.34497
    Left Arm D1 momentum                     : 0.000687025
    Left Arm D1 NMR                          : 0.310393
    Left Arm Q3 power supply current         : -0.00664289
    Left Arm Q3 momentum                     : -1.69219e-05
    Left Arm Q3 gauss meter                  : -2.074e-05
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.0534066
    Right Arm Q1 momentum                    : 0.00112407
    Right Arm Q1 gauss meter                 : -4.12e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.00753529
    Right Arm Q2 momentum                    : -1.7509e-05
    Right Arm Q2 gauss meter                 : 7.97e-05
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.8886
    Right Arm D1 momentum                    : 0.00186657
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : -0.00270882
    Right Arm Q3 momentum                    : -6.80764e-06
    Right Arm Q3 gauss meter                 : -0.0002775
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.41602
    Left Arm Bottom VDC Current              : 1.46484
    Right Arm Top VDC Current                : -1.70898
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 0.0175781
    Left Arm Bottom VDC voltage              : 0.0180664
    Right Arm Top VDC voltage                : -0.0117188
    Right Arm Bottom VDC voltage             : -0.0102539
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0266615
    Current on Unser monitor                 : 3.55701
    Current on Upstream bcm                  : 0.0392106
    Current on Downstream bcm                : 0.0141125
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 5.85569e-38
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                :  MBSY1C_energy --- Invalid channel name
    MBSY3c Hall C Beam energy                :  MBSY3C_energy --- Invalid channel name
    MBSY1c magnet current (amp)              :  MBSY1C --- Invalid channel name
    MBSY1c Bdl                               :  MBSY1C.BDL --- Invalid channel name
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.62002
    HacL_HPE1313A:0_Ch58                     : -0.21582
    HacL_HPE1313A:0_Ch55                     : 23.1934
    HacL_HPE1313A:0_Ch54                     : 0.015625
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.00454102
    HacR_HPE1313A:0_Ch58                     : -0.629395
    HacR_HPE1313A:0_Ch55                     : 22.4609
    HacR_HPE1313A:0_Ch54                     : -0.964844
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 0
    temperature loop 3-1                      : 19
    temperature loop 3-2                      : 19
    temperature loop 3-3                      : 0.92
    pressure fill target H2                   : 45.1133
    pressure fill bottle H2                   : 44.9973
    pressure ballast H2                       : 44.6723
    pressure exhaust H2                       : 45.1072
    cryogen input temp                        : 13.4
    crogen return flow                        : 0.205161
     JT valve setting                         : 52.5391
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13448 -d '2009-10-21 01:09:04' -t 0 -s IN