• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 02:00:48 on October 21, 2009

    Entry number 295916

    keyword=Start_Parity_Run_13450__CODA_Config=HapSimple_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=det linearity tests, detvHV just turned on ,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=25cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 13450 at Wed Oct 21 01:57:47 EDT 2009
    CODA Configuration: HapSimple
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       :  compton:RUN --- Invalid channel name
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.88
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.753
    Gun2: PC (PITA) NEG                      : 5.947
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00977
    Pockels Cell Voltage NEG                 : 1.83394
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              :  COMPTON_LASERP_si --- Invalid channel name
    Calculated power in cavity               :  COMPTON_PW1PCAV_ca --- Invalid channel name
    Photodiode on table                      :  COMPTON_PW2PCAV_ca --- Invalid channel name
    Laser X position on QPD 1                :  COMPTON_Y1SS_ca --- Invalid channel name
    Laser Y position on QPD 1                :  COMPTON_X1SS_ca --- Invalid channel name
    Laser X position on QPD 2                :  COMPTON_Y2SS_ca --- Invalid channel name
    Laser Y position on QPD 2                :  COMPTON_X2SS_ca --- Invalid channel name
    QPD 1 sum                                :  COMPTON_XYSUM1_ca --- Invalid channel name
    QPD 2 sum                                :  COMPTON_XYSUM2_ca --- Invalid channel name
    Position set point for adjustable 
                   mirror 1 (either x or y)  :  COMPTON_POS1_si --- Invalid channel name
    Position set point for adjustable 
                   mirror 2 (either x or y)  :  COMPTON_POS3_si --- Invalid channel name
    Laser minimum temperature (35.8)         :  COMPTON_LASERT_MIN --- Invalid channel name
    Laser temperature set point              :  COMPTON_LASERT_si --- Invalid channel name
    Polarisation in cavity                   :  COMPTON_SU_POLAR_mo --- Invalid channel name
    Reflection photodiode                    :  COMPTON_SERVO_PDRai --- Invalid channel name
    Gain of locking servo                    :  COMPTON_SERVO_GAINao --- Invalid channel name
    Tracking level (V) of locking servo      :  COMPTON_SERVO_SEUILao --- Invalid channel name
    Slow locking signal sent to laser        :  COMPTON_SERVO_SLOWai --- Invalid channel name
    Fast locking signal sent to laser        :  COMPTON_SERVO_FASTai --- Invalid channel name
    Calculated polarisation in cavity        :  COMPTON_CAVPOLAR_ca --- Invalid channel name
    Photodiode 1 after Wollaston prism       :  COMPTON_PW1R_S1_ca --- Invalid channel name
    Photodiode 2 after Wollaston prism       :  COMPTON_PW1R_S2_ca --- Invalid channel name
    Step size for RHWP scan                  :  COMPTON_PVAL_Y_ao --- Invalid channel name
    Laser temp slow ramp (1 = on)            :  COMPTON_CAVSLOW_bo --- Invalid channel name
    Extent of laser temp slow ramp (C)       :  COMPTON_LASERT_RAMPDT --- Invalid channel name
    Speed of laser temp slow ramp up         :  COMPTON_CAVPLUSOFT_ca.B --- Invalid channel name
    Speed of laser temp slow ramp down       : 
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     :  MF7b1461_2ch9property.F --- Invalid channel name
    S0 Front End, HV - Left Slot7 Card2 Ch9    :  MF7b1461_2ch1property.F --- Invalid channel name
    S0 Back End, HV - Left Slot7 Card2 Ch9  :  MF7b1461_2ch7property.F --- Invalid channel name
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.0534066
    Left Arm Q1 momentum                     : 7.35376e-05
    Left Arm Q1 gauss meter                  : 0.0003137
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.016585
    Left Arm Q2 momentum                     : 0.00212624
    Left Arm Q2 gauss meter                  : 0.0006354
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.34555
    Left Arm D1 momentum                     : 0.000695655
    Left Arm D1 NMR                          : 0.310379
    Left Arm Q3 power supply current         : -0.00685353
    Left Arm Q3 momentum                     : -1.72148e-05
    Left Arm Q3 gauss meter                  : -1.844e-05
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.0534066
    Right Arm Q1 momentum                    : 0.00115058
    Right Arm Q1 gauss meter                 : -4.17e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.00766839
    Right Arm Q2 momentum                    : -1.78183e-05
    Right Arm Q2 gauss meter                 : 9.7e-06
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.8884
    Right Arm D1 momentum                    : 0.00186766
    Right Arm D1 NMR                         : 0
    Right Arm Q3 power supply current        : -0.00237629
    Right Arm Q3 momentum                    : -5.97195e-06
    Right Arm Q3 gauss meter                 : -0.0002753
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.46484
    Left Arm Bottom VDC Current              : 1.46484
    Right Arm Top VDC Current                : -1.66016
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 0.0180664
    Left Arm Bottom VDC voltage              : 0.0195312
    Right Arm Top VDC voltage                : -0.0112305
    Right Arm Bottom VDC voltage             : -0.00830078
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0269755
    Current on Unser monitor                 : 3.748
    Current on Upstream bcm                  : 0.0399289
    Current on Downstream bcm                : 0.0140222
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 5.85569e-38
    Tiefenbach Hall A energy                 : 0
    Tiefenbach Hall C energy                 : 0
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                :  MBSY1C_energy --- Invalid channel name
    MBSY3c Hall C Beam energy                :  MBSY3C_energy --- Invalid channel name
    MBSY1c magnet current (amp)              :  MBSY1C --- Invalid channel name
    MBSY1c Bdl                               :  MBSY1C.BDL --- Invalid channel name
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.620068
    HacL_HPE1313A:0_Ch58                     : -0.215332
    HacL_HPE1313A:0_Ch55                     : 23.1445
    HacL_HPE1313A:0_Ch54                     : 0.0170898
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.00668945
    HacR_HPE1313A:0_Ch58                     : -0.630859
    HacR_HPE1313A:0_Ch55                     : 22.4121
    HacR_HPE1313A:0_Ch54                     : -0.967285
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 0
    temperature loop 3-1                      : 19
    temperature loop 3-2                      : 19
    temperature loop 3-3                      : 0.92
    pressure fill target H2                   : 44.5533
    pressure fill bottle H2                   : 44.622
    pressure ballast H2                       : 43.9368
    pressure exhaust H2                       : 44.596
    cryogen input temp                        : 13.4
    crogen return flow                        : 0
     JT valve setting                         : 52.5879
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13450 -d '2009-10-21 01:57:21' -t 0 -s IN