    User name apar

    Log entry time 09:47:57 on October 21, 2009

    Entry number 295934

    keyword=Start_Parity_Run_13455__CODA_Config=HapNoQweak_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=det linearity tests, no beam, 10 cycles, increased DAC16 to 51500 on right arm,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 13455 at Wed Oct 21 09:47:50 EDT 2009
    CODA Configuration: HapNoQweak
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 0
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 0
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.88
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.753
    Gun2: PC (PITA) NEG                      : 5.947
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.85836
    Pockels Cell Voltage NEG                 : 1.80708
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr 31mW
    Calculated power in cavity               : 0.122031
    Photodiode on table                      : -0.0041999
    Laser X position on QPD 1                : -443.656
    Laser Y position on QPD 1                : 980.312
    Laser X position on QPD 2                : -7.18596e+06
    Laser Y position on QPD 2                : -442.424
    QPD 1 sum                                : -0.00122085
    QPD 2 sum                                : -7.45058e-08
    Position set point for adjustable 
                   mirror 1 (either x or y)  : Home (0[c])
    Position set point for adjustable 
                   mirror 2 (either x or y)  : Home (0[c])
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2938
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.051883
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : -2.8145
    Calculated polarisation in cavity        : 15.4815
    Photodiode 1 after Wollaston prism       : 0.00556894
    Photodiode 2 after Wollaston prism       : 0.0040758
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1590.2
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1699.6
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -1698.6
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0.0534066
    Left Arm Q1 momentum                     : 0.000306667
    Left Arm Q1 gauss meter                  : 0.0002984
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0154244
    Left Arm Q2 momentum                     : 0.00236024
    Left Arm Q2 gauss meter                  : 0.0006732
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.33986
    Left Arm D1 momentum                     : 0.000663085
    Left Arm D1 NMR                          : 0.190378
    Left Arm Q3 power supply current         : -0.0077563
    Left Arm Q3 momentum                     : -1.94824e-05
    Left Arm Q3 gauss meter                  : 0.00063374
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.000227996
    Right Arm Q1 gauss meter                 : -1.68e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0096428
    Right Arm Q2 momentum                    : -2.2406e-05
    Right Arm Q2 gauss meter                 : -0.0003155
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.88338
    Right Arm D1 momentum                    : 0.00189546
    Right Arm D1 NMR                         : 0.167991
    Right Arm Q3 power supply current        : -0.0033963
    Right Arm Q3 momentum                    : -8.53538e-06
    Right Arm Q3 gauss meter                 : -0.0002753
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.51367
    Left Arm Bottom VDC Current              : 1.46484
    Right Arm Top VDC Current                : -1.75781
    Right Arm Bottom VDC Current             : -1.36719
    Left Arm Top VDC voltage                 : 0.0180664
    Left Arm Bottom VDC voltage              : 0.019043
    Right Arm Top VDC voltage                : -0.012207
    Right Arm Bottom VDC voltage             : -0.00976562
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0272746
    Current on Unser monitor                 : 2.65366
    Current on Upstream bcm                  : 0.0411167
    Current on Downstream bcm                : 0.0134325
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 5.85569e-38
    Tiefenbach Hall A energy                 : 3483.92
    Tiefenbach Hall C energy                 : 2344.17
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 1.33514e-05
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.620166
    HacL_HPE1313A:0_Ch58                     : -0.213867
    HacL_HPE1313A:0_Ch55                     : 23.0469
    HacL_HPE1313A:0_Ch54                     : 0.0170898
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.00668945
    HacR_HPE1313A:0_Ch58                     : -0.630859
    HacR_HPE1313A:0_Ch55                     : 22.1191
    HacR_HPE1313A:0_Ch54                     : -0.970703
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 0
    temperature loop 3-1                      : 19
    temperature loop 3-2                      : 19
    temperature loop 3-3                      : 0.92
    pressure fill target H2                   : 41.1444
    pressure fill bottle H2                   : 41.1582
    pressure ballast H2                       : 40.914
    pressure exhaust H2                       : 41.2085
    cryogen input temp                        : 13.4
    crogen return flow                        : 0.366877
     JT valve setting                         : 52.6367
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13455 -d '2009-10-21 09:47:31' -t 0 -s IN