User name apar
Log entry time 10:10:34 on October 22, 2009
Entry number 296089
keyword=Start_Parity_Run_13509__CODA_Config=Happex_Run_type=Pedestal,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13509 at Thu Oct 22 10:10:27 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20599
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 65
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 10
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.88
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.753
Gun2: PC (PITA) NEG : 5.947
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01709
Pockels Cell Voltage NEG : 1.82418
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 792.001
Photodiode on table : 419.242
Laser X position on QPD 1 : 149.347
Laser Y position on QPD 1 : 405.31
Laser X position on QPD 2 : -15.4613
Laser Y position on QPD 2 : -512.46
QPD 1 sum : -2.34633
QPD 2 sum : -1.69688
Position set point for adjustable
mirror 1 (either x or y) : 100[c]
Position set point for adjustable
mirror 2 (either x or y) : -110[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1852
Polarisation in cavity : RIGHT
Reflection photodiode : 0.413233
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : -0.858817
Fast locking signal sent to laser : 9.8059
Calculated polarisation in cavity : 78.4247
Photodiode 1 after Wollaston prism : 6.75261
Photodiode 2 after Wollaston prism : 55.8432
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -3.3
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0.640879
Left Arm Q1 momentum : 0.00101701
Left Arm Q1 gauss meter : 0.000244
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0127926
Left Arm Q2 momentum : 0.00234836
Left Arm Q2 gauss meter : 0.0006859
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.4198
Left Arm D1 momentum : 0.00179384
Left Arm D1 NMR : 0.500702
Left Arm Q3 power supply current : -0.0068272
Left Arm Q3 momentum : -1.71487e-05
Left Arm Q3 gauss meter : 0.00063428
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 4.77201e-05
Right Arm Q1 gauss meter : -2.09e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.013954
Right Arm Q2 momentum : -3.24234e-05
Right Arm Q2 gauss meter : -0.0003025
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.02722
Right Arm D1 momentum : 0.00199139
Right Arm D1 NMR : 0.161691
Right Arm Q3 power supply current : -0.00682623
Right Arm Q3 momentum : -1.84605e-05
Right Arm Q3 gauss meter : -0.0002599
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.51367
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0270854
Current on Unser monitor : 2.39841
Current on Upstream bcm : 0.0406171
Current on Downstream bcm : 0.0135536
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 2.17739
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.11
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.62002
HacL_HPE1313A:0_Ch58 : -0.214844
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0205078
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.00712891
HacR_HPE1313A:0_Ch58 : -0.634277
HacR_HPE1313A:0_Ch55 : 22.1191
HacR_HPE1313A:0_Ch54 : -0.972168
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202517
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 30.3243
pressure fill bottle H2 : 30.4311
pressure ballast H2 : 30.1045
pressure exhaust H2 : 30.66
cryogen input temp : 298.2
crogen return flow : 0.264243
JT valve setting : -0.439453
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13509 -d '2009-10-22 10:10:18' -t 3202517 -s IN