    User name apar

    Log entry time 12:02:57 on October 22, 2009

    Entry number 296097

    keyword=Start_Parity_Run_13513__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=LED crosstalk tests, both LEDs inside the det, both arms, new DAC16 setpoints test on left arm,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 13513 at Thu Oct 22 12:02:49 EDT 2009
    CODA Configuration: Happex
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20599
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 55
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 10
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.88
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.753
    Gun2: PC (PITA) NEG                      : 5.947
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.76068
    Pockels Cell Voltage NEG                 : 1.55556
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 790.076
    Photodiode on table                      : 418.993
    Laser X position on QPD 1                : 152.897
    Laser Y position on QPD 1                : 405.133
    Laser X position on QPD 2                : -16.1738
    Laser Y position on QPD 2                : -513.236
    QPD 1 sum                                : -2.34145
    QPD 2 sum                                : -1.68834
    Position set point for adjustable 
                   mirror 1 (either x or y)  : 100[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -110[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1852
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.401025
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : -0.492584
    Fast locking signal sent to laser        : 9.6887
    Calculated polarisation in cavity        : 78.4838
    Photodiode 1 after Wollaston prism       : 6.7178
    Photodiode 2 after Wollaston prism       : 55.7264
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1589.4
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -3.3
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -4.5
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000140816
    Left Arm Q1 gauss meter                  : 0.0003
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0128824
    Left Arm Q2 momentum                     : 0.00222476
    Left Arm Q2 gauss meter                  : 0.0006578
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.33491
    Left Arm D1 momentum                     : 0.00211452
    Left Arm D1 NMR                          : 0.373066
    Left Arm Q3 power supply current         : -0.00610122
    Left Arm Q3 momentum                     : -1.4626e-05
    Left Arm Q3 gauss meter                  : 0.0006175
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.0534066
    Right Arm Q1 momentum                    : 0.000402969
    Right Arm Q1 gauss meter                 : -2.76e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0138172
    Right Arm Q2 momentum                    : -3.32052e-05
    Right Arm Q2 gauss meter                 : -0.0003001
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 2.01882
    Right Arm D1 momentum                    : 0.00200529
    Right Arm D1 NMR                         : 0.485811
    Right Arm Q3 power supply current        : 0.0850644
    Right Arm Q3 momentum                    : 0.00046289
    Right Arm Q3 gauss meter                 : -0.0002173
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.41602
    Left Arm Bottom VDC Current              : 1.46484
    Right Arm Top VDC Current                : -1.70898
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 0.0175781
    Left Arm Bottom VDC voltage              : 0.0180664
    Right Arm Top VDC voltage                : -0.0117188
    Right Arm Bottom VDC voltage             : -0.00976562
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0273949
    Current on Unser monitor                 : 2.09133
    Current on Upstream bcm                  : 0.0410995
    Current on Downstream bcm                : 0.0136903
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.225573
    Tiefenbach Hall A energy                 : 3483.92
    Tiefenbach Hall C energy                 : 2344.17
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 1.33514e-05
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.620068
    HacL_HPE1313A:0_Ch58                     : -0.212891
    HacL_HPE1313A:0_Ch55                     : 22.8027
    HacL_HPE1313A:0_Ch54                     : 0.0244141
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.00751953
    HacR_HPE1313A:0_Ch58                     : -0.630859
    HacR_HPE1313A:0_Ch55                     : 22.0215
    HacR_HPE1313A:0_Ch54                     : -0.975098
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 3202517
    temperature loop 3-1                      : 65.32
    temperature loop 3-2                      : 64.21
    temperature loop 3-3                      : 29.99
    pressure fill target H2                   : 38.5321
    pressure fill bottle H2                   : 38.3993
    pressure ballast H2                       : 38.1384
    pressure exhaust H2                       : 38.7182
    cryogen input temp                        : 21
    crogen return flow                        : 5.72273
     JT valve setting                         : 22.998
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13513 -d '2009-10-22 12:02:24' -t 3202517 -s IN