Make Followup Entry
User name apar
Log entry time 13:03:45 on October 22, 2009
Entry number 296107
keyword=Start_Parity_Run_13518__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=LED crosstalk tests, right arm: baseline outside, diff inside, left arm: both LEDs inside,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13518 at Thu Oct 22 13:03:38 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20599
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 10
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.88
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.753
Gun2: PC (PITA) NEG : 5.947
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.76313
Pockels Cell Voltage NEG : 1.558
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 802.787
Photodiode on table : 420.239
Laser X position on QPD 1 : 138.54
Laser Y position on QPD 1 : 409.056
Laser X position on QPD 2 : -11.7001
Laser Y position on QPD 2 : -512.662
QPD 1 sum : -2.31826
QPD 2 sum : -1.69322
Position set point for adjustable
mirror 1 (either x or y) : 100[c]
Position set point for adjustable
mirror 2 (either x or y) : -110[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1852
Polarisation in cavity : RIGHT
Reflection photodiode : 0.399805
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : -0.382714
Fast locking signal sent to laser : 9.72899
Calculated polarisation in cavity : 78.4808
Photodiode 1 after Wollaston prism : 6.82088
Photodiode 2 after Wollaston prism : 56.5725
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -3.3
S0 Back End, HV - Left Slot7 Card2 Ch9 : -4.5
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000362993
Left Arm Q1 gauss meter : 0.0002858
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0125679
Left Arm Q2 momentum : 0.00247328
Left Arm Q2 gauss meter : 0.0007143
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.34727
Left Arm D1 momentum : 0.00204131
Left Arm D1 NMR : 0.20652
Left Arm Q3 power supply current : -0.00627426
Left Arm Q3 momentum : -1.507e-05
Left Arm Q3 gauss meter : 0.00062033
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.0534066
Right Arm Q1 momentum : 0.00042948
Right Arm Q1 gauss meter : -2.81e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0131516
Right Arm Q2 momentum : -3.05591e-05
Right Arm Q2 gauss meter : -0.0003054
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.02999
Right Arm D1 momentum : 0.00196304
Right Arm D1 NMR : 0.175401
Right Arm Q3 power supply current : 0.0865926
Right Arm Q3 momentum : 0.000452256
Right Arm Q3 gauss meter : -0.0002192
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.0102539
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0272097
Current on Unser monitor : 2.3996
Current on Upstream bcm : 0.0406966
Current on Downstream bcm : 0.0137229
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00585917
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.17
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.620068
HacL_HPE1313A:0_Ch58 : -0.211914
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.0219727
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.00727539
HacR_HPE1313A:0_Ch58 : -0.62793
HacR_HPE1313A:0_Ch55 : 22.2168
HacR_HPE1313A:0_Ch54 : -0.978516
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202517
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 39.0967
pressure fill bottle H2 : 38.9761
pressure ballast H2 : 39.1058
pressure exhaust H2 : 39.0295
cryogen input temp : 125
crogen return flow : 0
JT valve setting : -0.0976562
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13518 -d '2009-10-22 13:03:15' -t 3202517 -s IN