User name apar
Log entry time 13:27:09 on October 23, 2009
Entry number 296309
keyword=Start_Parity_Run_13563__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=det linearity studies, both LEDs inside both arms,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13563 at Fri Oct 23 13:27:01 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20632
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 105
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 10
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.88
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.753
Gun2: PC (PITA) NEG : 5.947
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.73871
Pockels Cell Voltage NEG : 1.5409
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 797.285
Photodiode on table : 387.836
Laser X position on QPD 1 : 143.77
Laser Y position on QPD 1 : 404.144
Laser X position on QPD 2 : -19.0439
Laser Y position on QPD 2 : -513.912
QPD 1 sum : -2.58805
QPD 2 sum : -1.8275
Position set point for adjustable
mirror 1 (either x or y) : 100[c]
Position set point for adjustable
mirror 2 (either x or y) : -110[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1441
Polarisation in cavity : LEFT
Reflection photodiode : 0.413233
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.108039
Fast locking signal sent to laser : -10.0513
Calculated polarisation in cavity : 65.1836
Photodiode 1 after Wollaston prism : 10.9839
Photodiode 2 after Wollaston prism : 52.0439
Step size for RHWP scan : 3750
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -4.5
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0.640879
Left Arm Q1 momentum : 0.00159123
Left Arm Q1 gauss meter : 0.0002073
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0125005
Left Arm Q2 momentum : 0.00332923
Left Arm Q2 gauss meter : 0.0009089
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.34614
Left Arm D1 momentum : 0.00268046
Left Arm D1 NMR : 0.469606
Left Arm Q3 power supply current : 1.38181
Left Arm Q3 momentum : 0.00816442
Left Arm Q3 gauss meter : -0.00086674
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.0534066
Right Arm Q1 momentum : 0.000376458
Right Arm Q1 gauss meter : -2.35e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0118834
Right Arm Q2 momentum : -2.76123e-05
Right Arm Q2 gauss meter : 0.0004284
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.02637
Right Arm D1 momentum : 0.191508
Right Arm D1 NMR : 0.162396
Right Arm Q3 power supply current : 0.0882964
Right Arm Q3 momentum : 0.000461771
Right Arm Q3 gauss meter : -0.0002143
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.80664
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0275862
Current on Unser monitor : 2.54197
Current on Upstream bcm : 0.0414291
Current on Downstream bcm : 0.0137433
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 7.72923
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.14
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.62002
HacL_HPE1313A:0_Ch58 : -0.213379
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0170898
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.00922852
HacR_HPE1313A:0_Ch58 : -0.625488
HacR_HPE1313A:0_Ch55 : 21.875
HacR_HPE1313A:0_Ch54 : -0.983398
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202553
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 45.5512
pressure fill bottle H2 : 45.4353
pressure ballast H2 : 45.6703
pressure exhaust H2 : 45.3239
cryogen input temp : 233.9
crogen return flow : 10.8693
JT valve setting : -0.0488281
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13563 -d '2009-10-23 13:26:58' -t 3202553 -s IN