NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 20:37:04 on October 23, 2009
Entry number 296363
keyword=End_of_Parity_Run_13570__CODA_Config=Happex
************************************************
Run Number: 13570
End of Run Comment:
Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=det linearity tests, HV -1180/-1580 (R/L),dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 13570 at Fri Oct 23 20:36:55 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 105
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 10
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.88
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.753
Gun2: PC (PITA) NEG : 5.947
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.82906
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 722.126
Photodiode on table : 393.569
Laser X position on QPD 1 : 155.838
Laser Y position on QPD 1 : 400.933
Laser X position on QPD 2 : -18.9387
Laser Y position on QPD 2 : -504.952
QPD 1 sum : -2.51969
QPD 2 sum : -1.78111
Position set point for adjustable
mirror 1 (either x or y) : 100[c]
Position set point for adjustable
mirror 2 (either x or y) : 2070[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1921
Polarisation in cavity : LEFT
Reflection photodiode : 0.45596
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : -0.844168
Fast locking signal sent to laser : -0.0897273
Calculated polarisation in cavity : 97.9599
Photodiode 1 after Wollaston prism : 0.58174
Photodiode 2 after Wollaston prism : 56.4486
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1580.2
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -4.5
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00110932
Left Arm Q1 gauss meter : 0.0002441
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0160684
Left Arm Q2 momentum : 0.00334374
Left Arm Q2 gauss meter : 0.0009088
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 48.6068
Left Arm D1 momentum : 0.151101
Left Arm D1 NMR : 0.332452
Left Arm Q3 power supply current : 51.2584
Left Arm Q3 momentum : 0.134129
Left Arm Q3 gauss meter : -0.026042
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.106813
Right Arm Q1 momentum : 0.000906681
Right Arm Q1 gauss meter : -3.71e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0112253
Right Arm Q2 momentum : -2.67703e-05
Right Arm Q2 gauss meter : 0.0004064
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 17.7973
Right Arm D1 momentum : 0.107486
Right Arm D1 NMR : 0.291843
Right Arm Q3 power supply current : -0.00629941
Right Arm Q3 momentum : -1.59534e-05
Right Arm Q3 gauss meter : -0.0002223
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.46484
Left Arm Bottom VDC Current : 1.46484
Right Arm Top VDC Current : -1.61133
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.0117188
Right Arm Bottom VDC voltage : -0.0102539
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0271168
Current on Unser monitor : 2.53045
Current on Upstream bcm : 0.0407146
Current on Downstream bcm : 0.0135191
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.0805817
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.17
Delta(E)/E width (MV_AI_DXWID) : 2.55307
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619922
HacL_HPE1313A:0_Ch58 : -0.216309
HacL_HPE1313A:0_Ch55 : 22.7539
HacL_HPE1313A:0_Ch54 : 0.0141602
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.0100098
HacR_HPE1313A:0_Ch58 : -0.630371
HacR_HPE1313A:0_Ch55 : 21.6797
HacR_HPE1313A:0_Ch54 : -0.98584
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202553
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 31.8883
pressure fill bottle H2 : 31.8181
pressure ballast H2 : 31.6503
pressure exhaust H2 : 32.1309
cryogen input temp : 192.7
crogen return flow : 14.4933
JT valve setting : 0
-----------------------------------------