NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 20:44:02 on October 23, 2009
Entry number 296366
keyword=Start_Parity_Run_13571__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=det linearity tests, HV -1180/-1580 (R/L),dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=73Hz,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13571 at Fri Oct 23 20:41:53 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 0
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 105
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 10
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.88
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.753
Gun2: PC (PITA) NEG : 5.947
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.82662
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 718.878
Photodiode on table : 393.819
Laser X position on QPD 1 : 156.42
Laser Y position on QPD 1 : 401.005
Laser X position on QPD 2 : -19.5533
Laser Y position on QPD 2 : -505.646
QPD 1 sum : -2.51724
QPD 2 sum : -1.77989
Position set point for adjustable
mirror 1 (either x or y) : 100[c]
Position set point for adjustable
mirror 2 (either x or y) : 2070[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1921
Polarisation in cavity : LEFT
Reflection photodiode : 0.453519
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : -0.836843
Fast locking signal sent to laser : -0.137338
Calculated polarisation in cavity : 97.9393
Photodiode 1 after Wollaston prism : 0.585408
Photodiode 2 after Wollaston prism : 56.2317
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1580.2
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : HacL_alignAGL --- Invalid channel name
Right Arm arm angle : HacR_alignAGL --- Invalid channel name
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : HacL_Q1_P0rb --- Invalid channel name
Left Arm Q1 gauss meter : HacL_Q1_LS450:FLD_DATA --- Invalid channel name
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : HacL_Q2_HP3458A:IOUT --- Invalid channel name
Left Arm Q2 momentum : HacL_Q2_P0rb --- Invalid channel name
Left Arm Q2 gauss meter : HacL_Q2_LS450:FLD_DATA --- Invalid channel name
Left Arm Q2 power supply polarity : HacL_VMIC1182:0_Ch17 --- Invalid channel name
Left Arm D1 power supply current : HacL_D1_HP3458A:IOUT --- Invalid channel name
Left Arm D1 momentum : HacL_D1_P0rb --- Invalid channel name
Left Arm D1 NMR : HacL_D1_NMR:SIG --- Invalid channel name
Left Arm Q3 power supply current : 1.38484
Left Arm Q3 momentum : 0.00810592
Left Arm Q3 gauss meter : -0.00084599
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : HacR_Q1_P0rb --- Invalid channel name
Right Arm Q1 gauss meter : HacR_Q1_LS450:FLD_DATA --- Invalid channel name
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : HacR_Q2_HP3458A:IOUT --- Invalid channel name
Right Arm Q2 momentum : HacR_Q2_P0rb --- Invalid channel name
Right Arm Q2 gauss meter : HacR_Q2_LS450:FLD_DATA --- Invalid channel name
Right Arm Q2 power supply polarity : HacR_VMIC1182:0_Ch17 --- Invalid channel name
Right Arm D1 power supply current : HacR_D1_HP3458A:IOUT --- Invalid channel name
Right Arm D1 momentum : HacR_D1_P0rb --- Invalid channel name
Right Arm D1 NMR : HacR_D1_NMR:SIG --- Invalid channel name
Right Arm Q3 power supply current : HacR_Q3_HP3458A:IOUT --- Invalid channel name
Right Arm Q3 momentum : HacR_Q3_P0rb --- Invalid channel name
Right Arm Q3 gauss meter : HacR_Q3_LS450:FLD_DATA --- Invalid channel name
Right Arm Q3 power supply polarity : HacR_VMIC1182:0_Ch26 --- Invalid channel name
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.66016
Right Arm Bottom VDC Current : -1.36719
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.0185547
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : -0.0102539
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0273456
Current on Unser monitor : 3.18713
Current on Upstream bcm : 0.0410491
Current on Downstream bcm : 0.0136421
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 2.08875
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.14
Delta(E)/E width (MV_AI_DXWID) : 2.55776
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 1.33514e-05
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619922
HacL_HPE1313A:0_Ch58 : -0.216797
HacL_HPE1313A:0_Ch55 : 22.8027
HacL_HPE1313A:0_Ch54 : 0.0136719
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.00981445
HacR_HPE1313A:0_Ch58 : -0.630371
HacR_HPE1313A:0_Ch55 : 21.6797
HacR_HPE1313A:0_Ch54 : -0.986328
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202553
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 31.7983
pressure fill bottle H2 : 31.8196
pressure ballast H2 : 31.6152
pressure exhaust H2 : 31.9265
cryogen input temp : 192.3
crogen return flow : 14.4647
JT valve setting : -0.0976562
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13571 -d '2009-10-23 20:41:50' -t 3202553 -s IN