User name apar
Log entry time 04:24:39 on October 25, 2009
Entry number 296563
keyword=End_of_Parity_Run_13586__CODA_Config=Happex
************************************************
Run Number: 13586
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=production on loop 1 (100uA). Right arm only,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=65Hz,target_type=25cm LH2
dithering on. MODULATION ON on MCC's part.
************************************************
End-of-Parity-run EPICS data for Run Number 13586 at Sun Oct 25 04:24:28 EDT 2009
CODA Configuration: Happex
Compton Run Number : 20670
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 211
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.16
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.24
Gun2: PC (PITA) NEG : 5.46
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.98535
Pockels Cell Voltage NEG : 1.83883
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 766.166
Photodiode on table : 393.819
Laser X position on QPD 1 : 109.761
Laser Y position on QPD 1 : 505.359
Laser X position on QPD 2 : -1.23895
Laser Y position on QPD 2 : -591.497
QPD 1 sum : -1.76158
QPD 2 sum : -1.29647
Position set point for adjustable
mirror 1 (either x or y) : -1450[c]
Position set point for adjustable
mirror 2 (either x or y) : -500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1491
Polarisation in cavity : LEFT
Reflection photodiode : 0.405909
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.170298
Fast locking signal sent to laser : -1.35689
Calculated polarisation in cavity : 98.113
Photodiode 1 after Wollaston prism : 0.571432
Photodiode 2 after Wollaston prism : 59.9952
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1699.6
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.67
Left Arm Q1 momentum : 3.14172
Left Arm Q1 gauss meter : -0.19933
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0163829
Left Arm Q2 momentum : 0.0037704
Left Arm Q2 gauss meter : 0.0010004
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5644
Left Arm D1 momentum : 0.300058
Left Arm D1 NMR : 0.680464
Left Arm Q3 power supply current : 101.143
Left Arm Q3 momentum : 0.260292
Left Arm Q3 gauss meter : -0.051253
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 2362.44
Right Arm Q1 momentum : 3.14181
Right Arm Q1 gauss meter : -0.05868
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.05
Right Arm Q2 momentum : 3.14161
Right Arm Q2 gauss meter : 0.7063
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.86
Right Arm D1 momentum : 3.14153
Right Arm D1 NMR : 1.16578
Right Arm Q3 power supply current : 1250.25
Right Arm Q3 momentum : 3.14206
Right Arm Q3 gauss meter : 0.5593
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.0180664
Right Arm Top VDC voltage : -0.00927734
Right Arm Bottom VDC voltage : -0.0107422
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 97.3261
Current on Unser monitor : 98.8726
Current on Upstream bcm : 95.0827
Current on Downstream bcm : 99.5696
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 106.296
Tiefenbach Hall A energy : 3482.96
Tiefenbach Hall C energy : 2344.12
Delta(E)/E width (MV_AI_DXWID) : 2.27191
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.470035
IPM1C12.YPOS : -0.119013
IPM1H04A.XPOS : -0.55795
IPM1H04A.YPOS : 1.42387
IPM1H04B.XPOS : -1.29779
IPM1H04B.YPOS : 2.09813
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0.492336
Survey Y offset bpm12 : -0.113559
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.62002
HacL_HPE1313A:0_Ch58 : -0.217285
HacL_HPE1313A:0_Ch55 : 22.6562
HacL_HPE1313A:0_Ch54 : 0.0170898
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0117188
HacR_HPE1313A:0_Ch58 : -0.626953
HacR_HPE1313A:0_Ch55 : 21.582
HacR_HPE1313A:0_Ch54 : -0.98291
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 33077684
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 30.6203
pressure fill bottle H2 : 30.7164
pressure ballast H2 : 30.425
pressure exhaust H2 : 30.6905
cryogen input temp : 180.8
crogen return flow : 19.5766
JT valve setting : -0.292969
-----------------------------------------