    User name apar

    Log entry time 14:08:09 on October 25, 2009

    Entry number 296621

    keyword=Start_Parity_Run_13594__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=spot++ Run,dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=65Hz,target_type=20cm LH2
    Beginning-of-Parity-run EPICS data for Run Number 13594 at Sun Oct 25 14:07:59 EDT 2009
    CODA Configuration: Happex
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20672
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 85
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.21
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 9.159
    Gun2: PC (PITA) NEG                      : 5.541
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.01954
    Pockels Cell Voltage NEG                 : 1.81929
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr741mW
    Calculated power in cavity               : 0.131822
    Photodiode on table                      : 400.05
    Laser X position on QPD 1                : 107.892
    Laser Y position on QPD 1                : 509.02
    Laser X position on QPD 2                : -1.21605
    Laser Y position on QPD 2                : -591.743
    QPD 1 sum                                : -1.7921
    QPD 2 sum                                : -1.31966
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1450[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -500[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1995
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.871025
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 0.986999
    Calculated polarisation in cavity        : 17.1835
    Photodiode 1 after Wollaston prism       : 0.00610442
    Photodiode 2 after Wollaston prism       : 0.00431415
    Step size for RHWP scan                  : 11162
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1589.4
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1699.6
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -5.3
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : 14.0003
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 2363.45
    Left Arm Q1 momentum                     : 3.14151
    Left Arm Q1 gauss meter                  : -0.1993
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0157502
    Left Arm Q2 momentum                     : 0.0034757
    Left Arm Q2 gauss meter                  : 0.0009422
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 98.5689
    Left Arm D1 momentum                     : 0.300086
    Left Arm D1 NMR                          : 0.611628
    Left Arm Q3 power supply current         : 101.144
    Left Arm Q3 momentum                     : 0.260277
    Left Arm Q3 gauss meter                  : -0.051254
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 2362.44
    Right Arm Q1 momentum                    : 3.14181
    Right Arm Q1 gauss meter                 : -0.05868
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1352.1
    Right Arm Q2 momentum                    : 3.14173
    Right Arm Q2 gauss meter                 : 0.7063
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1135.98
    Right Arm D1 momentum                    : 3.14163
    Right Arm D1 NMR                         : 1.16582
    Right Arm Q3 power supply current        : 1250.28
    Right Arm Q3 momentum                    : 3.14214
    Right Arm Q3 gauss meter                 : 0.5593
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.51367
    Left Arm Bottom VDC Current              : 1.51367
    Right Arm Top VDC Current                : -1.80664
    Right Arm Bottom VDC Current             : -1.46484
    Left Arm Top VDC voltage                 : 0.0185547
    Left Arm Bottom VDC voltage              : 0.0185547
    Right Arm Top VDC voltage                : -0.00927734
    Right Arm Bottom VDC voltage             : -0.0107422
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 5.02047
    Current on Unser monitor                 : 8.01603
    Current on Upstream bcm                  : 4.86299
    Current on Downstream bcm                : 5.17795
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 13.0623
    Tiefenbach Hall A energy                 : 3482.99
    Tiefenbach Hall C energy                 : 2344.12
    Delta(E)/E width (MV_AI_DXWID)           : 2.81576
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 145.346
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0.497934
    IPM1C12.YPOS                             : -0.0980119
    IPM1H04A.XPOS                            : -0.538619
    IPM1H04A.YPOS                            : 1.42141
    IPM1H04B.XPOS                            : -1.26835
    IPM1H04B.YPOS                            : 2.09479
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.475792
    Survey Y offset bpm12                     : -0.103744
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.619971
    HacL_HPE1313A:0_Ch58                     : -0.216797
    HacL_HPE1313A:0_Ch55                     : 22.6562
    HacL_HPE1313A:0_Ch54                     : 0.0151367
    Left Arm Angle Floor Angle               : 14
    Left Arm Angle Vernier                   : 31.1
    Left Arm Scattering Angle                : 14.0003
    Right Arm Collimator                     : 0.027002
    HacR_HPE1313A:0_Ch58                     : -0.625
    HacR_HPE1313A:0_Ch55                     : 21.582
    HacR_HPE1313A:0_Ch54                     : -0.981934
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 3202548
    temperature loop 3-1                      : 99.99
    temperature loop 3-2                      : 99.99
    temperature loop 3-3                      : 29.99
    pressure fill target H2                   : 30.9773
    pressure fill bottle H2                   : 31.1574
    pressure ballast H2                       : 30.576
    pressure exhaust H2                       : 30.8721
    cryogen input temp                        : 169.7
    crogen return flow                        : 19.1949
     JT valve setting                         : -0.146484
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13594 -d '2009-10-25 14:07:38' -t 3202548 -s IN