Log entry time 15:40:57 on October 25, 2009
Entry number 296643
keyword=End_of_Parity_Run_13596__CODA_Config=Happex
************************************************
Run Number: 13596
End of Run Comment:
Run_type=Production,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=Production on Loop 1 (100uA),dithering_magnet=on,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=on,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=65Hz,target_type=20cm LH2
Problems with Right Q1
************************************************
End-of-Parity-run EPICS data for Run Number 13596 at Sun Oct 25 15:40:47 EDT 2009
CODA Configuration: Happex
Compton Run Number : 20674
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 65
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.178
Gun2: PC (PITA) NEG : 5.522
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.74359
Pockels Cell Voltage NEG : 1.5409
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 607.016
Photodiode on table : 390.578
Laser X position on QPD 1 : 111.222
Laser Y position on QPD 1 : 506.411
Laser X position on QPD 2 : -2.09451
Laser Y position on QPD 2 : -592.363
QPD 1 sum : -1.75792
QPD 2 sum : -1.27815
Position set point for adjustable
mirror 1 (either x or y) : -1450[c]
Position set point for adjustable
mirror 2 (either x or y) : -500[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2938
Polarisation in cavity : LEFT
Reflection photodiode : 0.510895
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.228896
Fast locking signal sent to laser : -1.1518
Calculated polarisation in cavity : 98.1012
Photodiode 1 after Wollaston prism : 0.455475
Photodiode 2 after Wollaston prism : 47.52
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1589.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -4
S0 Back End, HV - Left Slot7 Card2 Ch9 : -5.3
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.56
Left Arm Q1 momentum : 3.14158
Left Arm Q1 gauss meter : -0.19933
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.015855
Left Arm Q2 momentum : 0.0035883
Left Arm Q2 gauss meter : 0.0009678
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 98.5669
Left Arm D1 momentum : 0.300086
Left Arm D1 NMR : 0.639375
Left Arm Q3 power supply current : 101.145
Left Arm Q3 momentum : 0.260282
Left Arm Q3 gauss meter : -0.051255
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.106813
Right Arm Q1 momentum : 0.00140509
Right Arm Q1 gauss meter : -4.41e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1352.11
Right Arm Q2 momentum : 3.14175
Right Arm Q2 gauss meter : 0.7064
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1135.98
Right Arm D1 momentum : 3.14151
Right Arm D1 NMR : 1.16578
Right Arm Q3 power supply current : 1250.3
Right Arm Q3 momentum : 3.14217
Right Arm Q3 gauss meter : 0.5594
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.41602
Right Arm Top VDC Current : -1.85547
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0180664
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.00927734
Right Arm Bottom VDC voltage : -0.0102539
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0328124
Current on Unser monitor : 2.89126
Current on Upstream bcm : 0.0420067
Current on Downstream bcm : 0.0236182
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 2.21099
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.17
Delta(E)/E width (MV_AI_DXWID) : 2.7996
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619971
HacL_HPE1313A:0_Ch58 : -0.217773
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : 0.015625
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.0233887
HacR_HPE1313A:0_Ch58 : -0.625488
HacR_HPE1313A:0_Ch55 : 21.582
HacR_HPE1313A:0_Ch54 : -0.982422
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
Arc OTR x-position : -10.5973
Arc OTR y-position : 5
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 33077684
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 29.8726
pressure fill bottle H2 : 29.9657
pressure ballast H2 : 30.6264
pressure exhaust H2 : 29.2058
cryogen input temp : 172.4
crogen return flow : 19.4892
JT valve setting : -0.146484
-----------------------------------------