NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 21:22:13 on October 26, 2009
Entry number 296780
keyword=Start_Parity_Run_13605__CODA_Config=Happex_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=Al background studies, parity daq for unser, 5uA beam, -0.5 mm in x BPMB,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=65Hz,target_type=25cm LH2
Beginning-of-Parity-run EPICS data for Run Number 13605 at Mon Oct 26 21:22:05 EDT 2009
CODA Configuration: Happex
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20696
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 80
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.178
Gun2: PC (PITA) NEG : 5.522
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00733
Pockels Cell Voltage NEG : 1.84371
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 971.479
Photodiode on table : 403.041
Laser X position on QPD 1 : 115.775
Laser Y position on QPD 1 : 501.48
Laser X position on QPD 2 : 2.02681
Laser Y position on QPD 2 : -597.468
QPD 1 sum : -1.83849
QPD 2 sum : -1.32088
Position set point for adjustable
mirror 1 (either x or y) : 50[c]
Position set point for adjustable
mirror 2 (either x or y) : -620[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1578
Polarisation in cavity : RIGHT
Reflection photodiode : 0.353415
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.0860647
Fast locking signal sent to laser : 1.94287
Calculated polarisation in cavity : 97.8415
Photodiode 1 after Wollaston prism : 76.2303
Photodiode 2 after Wollaston prism : 0.831677
Step size for RHWP scan : 11162
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -2099.5
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1699.6
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1699.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : 14.0003
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 2363.99
Left Arm Q1 momentum : 3.14229
Left Arm Q1 gauss meter : -0.19931
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1352.65
Left Arm Q2 momentum : 3.14131
Left Arm Q2 gauss meter : 0.7098
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1103.4
Left Arm D1 momentum : 3.14164
Left Arm D1 NMR : 1.1634
Left Arm Q3 power supply current : 1250.48
Left Arm Q3 momentum : 3.14097
Left Arm Q3 gauss meter : -0.63062
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000710498
Right Arm Q1 gauss meter : -3.34e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -3.80449
Right Arm Q2 momentum : -0.00884009
Right Arm Q2 gauss meter : 0.000523
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 0.0273265
Right Arm D1 momentum : 0.00553784
Right Arm D1 NMR : 1.72097
Right Arm Q3 power supply current : 0.000261541
Right Arm Q3 momentum : 0.000428188
Right Arm Q3 gauss meter : -0.0002241
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 0.292969
Left Arm Bottom VDC Current : 0.683594
Right Arm Top VDC Current : -1.80664
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 3.99561
Left Arm Bottom VDC voltage : 4.00098
Right Arm Top VDC voltage : -0.00830078
Right Arm Bottom VDC voltage : -0.00976562
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 4.91095
Current on Unser monitor : 7.1967
Current on Upstream bcm : 4.75962
Current on Downstream bcm : 5.06228
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 12.7429
Tiefenbach Hall A energy : 3482.96
Tiefenbach Hall C energy : 2344.14
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 145.346
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0.523111
IPM1C12.YPOS : -0.113921
IPM1H04A.XPOS : -0.116211
IPM1H04A.YPOS : 1.60901
IPM1H04B.XPOS : -1.79698
IPM1H04B.YPOS : 2.09348
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.489812
Survey Y offset bpm12 : -0.113921
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.62002
HacL_HPE1313A:0_Ch58 : -0.212891
HacL_HPE1313A:0_Ch55 : 22.9004
HacL_HPE1313A:0_Ch54 : 0.0112305
Left Arm Angle Floor Angle : 14
Left Arm Angle Vernier : 31.1
Left Arm Scattering Angle : 14.0003
Right Arm Collimator : 0.027832
HacR_HPE1313A:0_Ch58 : -0.630859
HacR_HPE1313A:0_Ch55 : 21.7285
HacR_HPE1313A:0_Ch54 : -0.980469
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 17740754
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 30.6661
pressure fill bottle H2 : 30.8446
pressure ballast H2 : 30.4463
pressure exhaust H2 : 30.9529
cryogen input temp : 185.5
crogen return flow : 13.1076
JT valve setting : -0.488281
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/dalton/runlistDB/addRun2runlist.pl -r 13605 -d '2009-10-26 21:22:00' -t 17740754 -s IN