User name apar
Log entry time 11:38:03 on October 30, 2009
Entry number 296933
keyword=Start_Parity_Run_13639__CODA_Config=PvdNoQweak_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=check new ADC18 lib,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13639 at Fri Oct 30 11:37:51 EDT 2009
CODA Configuration: PvdNoQweak
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20728
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 90
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 0
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.178
Gun2: PC (PITA) NEG : 5.522
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.01709
Pockels Cell Voltage NEG : 1.82906
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.139275
Photodiode on table : 398.056
Laser X position on QPD 1 : -52.6569
Laser Y position on QPD 1 : -506.043
Laser X position on QPD 2 : 75.0057
Laser Y position on QPD 2 : -287.666
QPD 1 sum : -1.86169
QPD 2 sum : -2.43545
Position set point for adjustable
mirror 1 (either x or y) : Home (0[c])
Position set point for adjustable
mirror 2 (either x or y) : Home (0[c])
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1573
Polarisation in cavity : RIGHT
Reflection photodiode : 0.06287
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : -2.57645
Calculated polarisation in cavity : 20.65
Photodiode 1 after Wollaston prism : 0.00655957
Photodiode 2 after Wollaston prism : 0.00431415
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -2099.5
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1699.6
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1699.4
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000256599
Left Arm Q1 gauss meter : 0.0002926
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0140879
Left Arm Q2 momentum : 9.45679e-05
Left Arm Q2 gauss meter : 0.0001735
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.33533
Left Arm D1 momentum : 0.000692592
Left Arm D1 NMR : 0.310541
Left Arm Q3 power supply current : -0.00612756
Left Arm Q3 momentum : -1.53913e-05
Left Arm Q3 gauss meter : 0.00063709
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000970308
Right Arm Q1 gauss meter : -3.83e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.013843
Right Arm Q2 momentum : -3.29818e-05
Right Arm Q2 gauss meter : -0.0002914
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -1446.15
Right Arm D1 momentum : 0.00205571
Right Arm D1 NMR : 12.7943
Right Arm Q3 power supply current : -0.00864955
Right Arm Q3 momentum : -2.25169e-05
Right Arm Q3 gauss meter : -0.0002743
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 1.41602
Left Arm Bottom VDC Current : 1.51367
Right Arm Top VDC Current : -1.70898
Right Arm Bottom VDC Current : -1.41602
Left Arm Top VDC voltage : 0.0185547
Left Arm Bottom VDC voltage : 0.019043
Right Arm Top VDC voltage : -0.012207
Right Arm Bottom VDC voltage : -0.012207
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0277071
Current on Unser monitor : 17.3116
Current on Upstream bcm : 0.0415064
Current on Downstream bcm : 0.0139079
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 8.00526
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.13
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619238
HacL_HPE1313A:0_Ch58 : -0.260254
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.046875
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.0195312
HacR_HPE1313A:0_Ch58 : -0.662598
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.851562
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 12674482
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 16.846
pressure fill bottle H2 : 17.1435
pressure ballast H2 : 17.5509
pressure exhaust H2 : 17.3297
cryogen input temp : 298.6
crogen return flow : 0
JT valve setting : -0.146484
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13639 -d '2009-10-30 11:37:49' -t 12674482 -s IN