    User name apar

    Log entry time 18:38:07 on October 31, 2009

    Entry number 297046

    keyword=End_of_Parity_Run_13670__CODA_Config=Pvdis
    ************************************************
     Run Number: 13670
     End of Run Comment:
    
    Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=panguin and prompt test,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13670 at Sat Oct 31 18:37:53 EDT 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20745
    -----------------------------------------
    Wien angle                               : 17.1968
    Wien BDL                                 : 395.55
    Wien field                               : 11.363
    Laser attenuation Hall A                 : 90
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 9.178
    Gun2: PC (PITA) NEG                      : 5.522
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00244
    Pockels Cell Voltage NEG                 : 1.8315
    G0 Helicity Settle Set                   : 500 usec
    G0 Helicity Delay Set                    : 8 cycles
    G0 Helicity Pattern Set                  : Quartet
    G0 Helicity Random/Toggle Set            : Random
    G0 Helicity Settle Read                  : 500 usec
    G0 Helicity Delay Read                   : 8 cycles
    G0 Helicity Pattern Read                 : Quartet
    G0 Helicity Random/Toggle Read           : Random
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 0.14598
    Photodiode on table                      : 403.041
    Laser X position on QPD 1                : 191.19
    Laser Y position on QPD 1                : 396.586
    Laser X position on QPD 2                : -21.1961
    Laser Y position on QPD 2                : -541.172
    QPD 1 sum                                : -2.50137
    QPD 2 sum                                : -1.64195
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -2375[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -3690[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1125
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.872246
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : 2.01978
    Calculated polarisation in cavity        : 52.445
    Photodiode 1 after Wollaston prism       : 0.0130656
    Photodiode 2 after Wollaston prism       : 0.0040758
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.015
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1548.8
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1600.1
    S0 Back End, HV - Left Slot7 Card2 Ch9    : -1799.6
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000475647
    Left Arm Q1 gauss meter                  : 0.0002906
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0151586
    Left Arm Q2 momentum                     : 0.000226083
    Left Arm Q2 gauss meter                  : 0.0002034
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.33956
    Left Arm D1 momentum                     : 0.000655012
    Left Arm D1 NMR                          : 0.310462
    Left Arm Q3 power supply current         : -0.0060937
    Left Arm Q3 momentum                     : -1.42858e-05
    Left Arm Q3 gauss meter                  : 0.00063428
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.000710498
    Right Arm Q1 gauss meter                 : -1.24e-05
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : -0.0139133
    Right Arm Q2 momentum                    : -3.01982e-05
    Right Arm Q2 gauss meter                 : -0.0002964
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : -1409.47
    Right Arm D1 momentum                    : 0.00210721
    Right Arm D1 NMR                         : 0.291932
    Right Arm Q3 power supply current        : -0.00354202
    Right Arm Q3 momentum                    : -7.8687e-06
    Right Arm Q3 gauss meter                 : -0.0002734
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 1.46484
    Left Arm Bottom VDC Current              : 1.41602
    Right Arm Top VDC Current                : -1.70898
    Right Arm Bottom VDC Current             : -1.41602
    Left Arm Top VDC voltage                 : 0.0180664
    Left Arm Bottom VDC voltage              : 0.019043
    Right Arm Top VDC voltage                : -0.012207
    Right Arm Bottom VDC voltage             : -0.0112305
    -----------------------------------------
     Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0256796
    Current on Unser monitor                 : 17.7159
    Current on Upstream bcm                  : 0.037876
    Current on Downstream bcm                : 0.0134832
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 8.34787
    Tiefenbach Hall A energy                 : 3483.92
    Tiefenbach Hall C energy                 : 2344.11
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 3489.72
    MBSY3c Hall C Beam energy                : 2349.75
    MBSY1c magnet current (amp)              : 0
    MBSY1c Bdl                               : 870864
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.619238
    HacL_HPE1313A:0_Ch58                     : -0.232422
    HacL_HPE1313A:0_Ch55                     : 23.291
    HacL_HPE1313A:0_Ch54                     : 0.0493164
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0210449
    HacR_HPE1313A:0_Ch58                     : -0.660645
    HacR_HPE1313A:0_Ch55                     : 22.3145
    HacR_HPE1313A:0_Ch54                     : -0.854004
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -10.5973
    Arc OTR  y-position                      : 5
    Arc OTR  x-width                         : 0
    Arc OTR  y-width                         : -0
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 12674482
    temperature loop 3-1                      : 99.99
    temperature loop 3-2                      : 99.99
    temperature loop 3-3                      : 29.99
    pressure fill target H2                   : 17.1908
    pressure fill bottle H2                   : 17.3312
    pressure ballast H2                       : 17.6715
    pressure exhaust H2                       : 17.6196
    cryogen input temp                        : 298.6
    crogen return flow                        : 0.42865
     JT valve setting                         : -0.292969
    -----------------------------------------