User name apar
Log entry time 10:54:13 on November 2, 2009
Entry number 297157
keyword=Start_Parity_Run_13700__CODA_Config=PvdNoQweak_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=ovs=9, integ=1300 again,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13700 at Mon Nov 2 10:53:58 EST 2009
CODA Configuration: PvdNoQweak
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20773
-----------------------------------------
Wien angle : 17.1968
Wien BDL : 395.55
Wien field : 11.363
Laser attenuation Hall A : 90
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 0
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.178
Gun2: PC (PITA) NEG : 5.522
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.76801
Pockels Cell Voltage NEG : 1.56532
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 951.119
Photodiode on table : 399.302
Laser X position on QPD 1 : 122.864
Laser Y position on QPD 1 : 512.618
Laser X position on QPD 2 : 17.6299
Laser Y position on QPD 2 : -607.161
QPD 1 sum : -1.60898
QPD 2 sum : -1.24763
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2750
Polarisation in cavity : RIGHT
Reflection photodiode : 0.364402
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.144662
Fast locking signal sent to laser : -5.90185
Calculated polarisation in cavity : 97.8829
Photodiode 1 after Wollaston prism : 74.415
Photodiode 2 after Wollaston prism : 0.79571
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1548.8
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1452.3
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1724.8
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 564.24
Left Arm Q1 momentum : 0.749989
Left Arm Q1 gauss meter : -0.04742
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 322.997
Left Arm Q2 momentum : 0.75011
Left Arm Q2 gauss meter : 0.16896
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 265.587
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.310525
Left Arm Q3 power supply current : 298.555
Left Arm Q3 momentum : 0.749914
Left Arm Q3 gauss meter : -0.149903
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 3.18134e-05
Right Arm Q1 gauss meter : -2.88e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.0149227
Right Arm Q2 momentum : -3.22344e-05
Right Arm Q2 gauss meter : -0.0002859
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -1400.27
Right Arm D1 momentum : 0.00207833
Right Arm D1 NMR : 0.304116
Right Arm Q3 power supply current : -0.00329916
Right Arm Q3 momentum : -9.31473e-06
Right Arm Q3 gauss meter : -0.0002767
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -2.00195
Left Arm Bottom VDC Current : 3.17383
Right Arm Top VDC Current : -29.248
Right Arm Bottom VDC Current : 0.439453
Left Arm Top VDC voltage : 3.99463
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4.00049
Right Arm Bottom VDC voltage : 4.00146
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0271096
Current on Unser monitor : 17.7302
Current on Upstream bcm : 0.0402634
Current on Downstream bcm : 0.0139558
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00484089
Tiefenbach Hall A energy : 3483.92
Tiefenbach Hall C energy : 2344.17
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3489.72
MBSY3c Hall C Beam energy : 2349.75
MBSY1c magnet current (amp) : 0
MBSY1c Bdl : 870864
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619287
HacL_HPE1313A:0_Ch58 : -0.230957
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : 0.0483398
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.0544434
HacR_HPE1313A:0_Ch58 : -0.650879
HacR_HPE1313A:0_Ch55 : 22.0215
HacR_HPE1313A:0_Ch54 : -0.862793
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202547
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 16.9039
pressure fill bottle H2 : 17.0748
pressure ballast H2 : 16.9863
pressure exhaust H2 : 17.3953
cryogen input temp : 298.8
crogen return flow : 1.73488
JT valve setting : -0.488281
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13700 -d '2009-11-02 10:53:51' -t 3202547 -s IN