User name apar
Log entry time 16:18:24 on November 2, 2009
Entry number 297176
keyword=Start_Parity_Run_13707__CODA_Config=Pvdis_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13707 at Mon Nov 2 16:17:32 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20773
-----------------------------------------
Wien angle : 74.5273
Wien BDL : 1718.2
Wien field : 49.662
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 0
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.178
Gun2: PC (PITA) NEG : 5.522
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.76801
Pockels Cell Voltage NEG : 1.55311
G0 Helicity Settle Set : HELG0TSETTLEs --- Invalid channel name
G0 Helicity Delay Set : HELG0DELAYs --- Invalid channel name
G0 Helicity Pattern Set : HELG0PATTERNs --- Invalid channel name
G0 Helicity Random/Toggle Set : HELG0ORDERs --- Invalid channel name
G0 Helicity Settle Read : HELG0TSETTLEd --- Invalid channel name
G0 Helicity Delay Read : HELG0DELAYd --- Invalid channel name
G0 Helicity Pattern Read : HELG0PATTERNd --- Invalid channel name
G0 Helicity Random/Toggle Read : HELG0ORDERd --- Invalid channel name
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 938.813
Photodiode on table : 400.05
Laser X position on QPD 1 : 113.819
Laser Y position on QPD 1 : 517.891
Laser X position on QPD 2 : 20.9466
Laser Y position on QPD 2 : -605.927
QPD 1 sum : -1.58579
QPD 2 sum : -1.25252
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2809
Polarisation in cavity : RIGHT
Reflection photodiode : 0.379051
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : -0.58048
Fast locking signal sent to laser : -3.05622
Calculated polarisation in cavity : 97.9062
Photodiode 1 after Wollaston prism : 73.4244
Photodiode 2 after Wollaston prism : 0.776808
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1529.7
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1432
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1724.8
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0.694286
Left Arm Q1 momentum : 0.00217953
Left Arm Q1 gauss meter : 0.0001668
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0104939
Left Arm Q2 momentum : 0.00317836
Left Arm Q2 gauss meter : 0.0008746
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.43683
Left Arm D1 momentum : 0.00270885
Left Arm D1 NMR : 0.179014
Left Arm Q3 power supply current : 1.38128
Left Arm Q3 momentum : 0.00683548
Left Arm Q3 gauss meter : -0.00060114
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0.000673383
Right Arm Q1 gauss meter : -3.27e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0124602
Right Arm Q2 momentum : -2.88236e-05
Right Arm Q2 gauss meter : 0.0001908
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.10697
Right Arm D1 momentum : 0.00322568
Right Arm D1 NMR : 0.211197
Right Arm Q3 power supply current : -0.00700183
Right Arm Q3 momentum : -1.82351e-05
Right Arm Q3 gauss meter : 5.82e-05
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -1.12305
Left Arm Bottom VDC Current : 4.73633
Right Arm Top VDC Current : 5.41992
Right Arm Bottom VDC Current : -2.39258
Left Arm Top VDC voltage : 3.99707
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4
Right Arm Bottom VDC voltage : 4.00342
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0278131
Current on Unser monitor : 17.2383
Current on Upstream bcm : 0.041303
Current on Downstream bcm : 0.0143231
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.256168
Tiefenbach Hall A energy : 6070.24
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 6084.28
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.51834e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.619287
HacL_HPE1313A:0_Ch58 : -0.231445
HacL_HPE1313A:0_Ch55 : 23.3398
HacL_HPE1313A:0_Ch54 : 0.050293
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.0232422
HacR_HPE1313A:0_Ch58 : -0.65625
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.855469
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202547
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 16.8948
pressure fill bottle H2 : 17.0718
pressure ballast H2 : 16.8841
pressure exhaust H2 : 17.4044
cryogen input temp : 298.2
crogen return flow : 0
JT valve setting : -0.78125
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13707 -d '2009-11-02 16:10:48' -t 3202547 -s IN