    keyword=HallA FFB pause ECL signal polarity needs to be checked

    The hallA FFB pause ECL cable between the CH flexio board and ECL/NIM module 
    was loose or came loose during helicity/MPS polarity check in the counting 
    house. I plugged the ECL cable back into the ECL/NIM module. But I have not 
    verified that the polarity of the FFB pause signal is correct since the 
    Modulation is turned off (no channel access allowed right now from MCC), and I 
    cant turn the dithering magnets on. The FFB pause needs to be tested. If it is 
    not working then the polarity of the FFB pause ECL cable needs to be reversed.