    User name apar

    Log entry time 14:16:04 on November 3, 2009

    Entry number 297256

    keyword=End_of_Parity_Run_13715__CODA_Config=Pvdis
    ************************************************
     Run Number: 13715
     End of Run Comment:
    
    Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=new helicity board test, pairsynch/helicity restored to what it was before,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13715 at Tue Nov  3 14:15:47 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20811
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1724.8
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 70
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 0
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 9.178
    Gun2: PC (PITA) NEG                      : 5.522
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.01221
    Pockels Cell Voltage NEG                 : 1.81685
    Helicity Delay Set                    : 8 cycles
    Helicity Pattern Set                  : Quartet
    Helicity Settle Read                  : 500
    Helicity Delay Read                   : 8 cycles
    Helicity Pattern Read                 : Quartet
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 0.146327
    Photodiode on table                      : 395.813
    Laser X position on QPD 1                : 120.748
    Laser Y position on QPD 1                : 
    Laser X position on QPD 2                : 17.8575
    Laser Y position on QPD 2                : -602.42
    QPD 1 sum                                : -1.58335
    QPD 2 sum                                : -1.22932
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1520[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2270
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.871025
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 1.00165
    Calculated polarisation in cavity        : 17.8094
    Photodiode 1 after Wollaston prism       : 0.00655957
    Photodiode 2 after Wollaston prism       : 0.00457633
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.05
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 1
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1530.4
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1432
    S0 Back End, HV - Left Slot7 Card2 Ch9    : -1724.8
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000932517
    Left Arm Q1 gauss meter                  : 0.0002494
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0112875
    Left Arm Q2 momentum                     : 0.00288322
    Left Arm Q2 gauss meter                  : 0.0007883
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.34009
    Left Arm D1 momentum                     : 0.00291874
    Left Arm D1 NMR                          : 0.191167
    Left Arm Q3 power supply current         : 1.37978
    Left Arm Q3 momentum                     : 0.00687191
    Left Arm Q3 gauss meter                  : -0.00060639
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0
    Right Arm Q1 momentum                    : 0.00176564
    Right Arm Q1 gauss meter                 : -6.14e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0133291
    Right Arm Q2 momentum                    : -3.09715e-05
    Right Arm Q2 gauss meter                 : 0.0002016
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.88742
    Right Arm D1 momentum                    : 0.00309487
    Right Arm D1 NMR                         : 0.323463
    Right Arm Q3 power supply current        : -0.00653106
    Right Arm Q3 momentum                    : -1.54651e-05
    Right Arm Q3 gauss meter                 : 5.27e-05
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 5.27344
    Left Arm Bottom VDC Current              : -0.976562
    Right Arm Top VDC Current                : 26.1719
    Right Arm Bottom VDC Current             : 0.878906
    Left Arm Top VDC voltage                 : 3.99658
    Left Arm Bottom VDC voltage              : 4
    Right Arm Top VDC voltage                : 3.99854
    Right Arm Bottom VDC voltage             : 4.00342
    -----------------------------------------
     Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0251996
    Current on Unser monitor                 : 16.7577
    Current on Upstream bcm                  : 0.0373582
    Current on Downstream bcm                : 0.0130409
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 1.05968
    Tiefenbach Hall A energy                 : 6063.88
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 6077.87
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 1.51674e+06
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpmA                     : -0.63
    Survey Y offset bpmA                     : -0.9
    Survey X offset bpmB                     : 0.77
    Survey Y offset bpmB                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.618848
    HacL_HPE1313A:0_Ch58                     : -0.250977
    HacL_HPE1313A:0_Ch55                     : 23.3398
    HacL_HPE1313A:0_Ch54                     : 0.0952148
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0242188
    HacR_HPE1313A:0_Ch58                     : -0.654785
    HacR_HPE1313A:0_Ch55                     : 22.4121
    HacR_HPE1313A:0_Ch54                     : -0.849609
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    Arc OTR  x-position                      : -10.5973
    Arc OTR  y-position                      : 5
    Arc OTR  x-width                         : 0
    Arc OTR  y-width                         : -0
    Arc OTR  data valid flag                 : No
    Arc OTR  In/Out                          : OTR is Out
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 3202547
    temperature loop 3-1                      : 99.99
    temperature loop 3-2                      : 99.99
    temperature loop 3-3                      : 29.99
    pressure fill target H2                   : 16.6415
    pressure fill bottle H2                   : 16.8887
    pressure ballast H2                       : 16.8627
    pressure exhaust H2                       : 17.2839
    cryogen input temp                        : 297.1
    crogen return flow                        : 0
     JT valve setting                         : -1.02539
    -----------------------------------------