User name apar
Log entry time 18:55:22 on November 3, 2009
Entry number 297285
keyword=Start_Parity_Run_13719__CODA_Config=Pvdis_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=test panguin new online.C file,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=in,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13719 at Tue Nov 3 18:55:10 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20815
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 0
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 4.8
Gun2: PC (PITA) NEG : 9.9
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.67766
Pockels Cell Voltage NEG : 1.58974
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr736mW
Calculated power in cavity : 0.1441
Photodiode on table : 396.81
Laser X position on QPD 1 : 117.873
Laser Y position on QPD 1 : 517.049
Laser X position on QPD 2 : 17.7342
Laser Y position on QPD 2 : -604.691
QPD 1 sum : -1.57602
QPD 2 sum : -1.23787
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2539
Polarisation in cavity : RIGHT
Reflection photodiode : 0.871025
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 3.56528
Calculated polarisation in cavity : 19.5442
Photodiode 1 after Wollaston prism : 0.00674699
Photodiode 2 after Wollaston prism : 0.00450483
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 1
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1530.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1432
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1724.8
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0.0534066
Left Arm Q1 momentum : 0.00114531
Left Arm Q1 gauss meter : 0.0002268
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0106174
Left Arm Q2 momentum : 0.00296239
Left Arm Q2 gauss meter : 0.0008533
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.34498
Left Arm D1 momentum : 0.00298917
Left Arm D1 NMR : 0.177869
Left Arm Q3 power supply current : 1.38029
Left Arm Q3 momentum : 0.00683804
Left Arm Q3 gauss meter : -0.00060165
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.106813
Right Arm Q1 momentum : 0.00139449
Right Arm Q1 gauss meter : -4.63e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.012194
Right Arm Q2 momentum : -2.83425e-05
Right Arm Q2 gauss meter : 0.0001934
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.88842
Right Arm D1 momentum : 0.00310005
Right Arm D1 NMR : 0.188769
Right Arm Q3 power supply current : -0.00686733
Right Arm Q3 momentum : -1.62914e-05
Right Arm Q3 gauss meter : 5.35e-05
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : -1.41602
Left Arm Bottom VDC Current : 3.07617
Right Arm Top VDC Current : -0.488281
Right Arm Bottom VDC Current : -3.22266
Left Arm Top VDC voltage : 3.99365
Left Arm Bottom VDC voltage : 4
Right Arm Top VDC voltage : 3.99658
Right Arm Bottom VDC voltage : 4.02051
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0252704
Current on Unser monitor : 17.9937
Current on Upstream bcm : 0.0375466
Current on Downstream bcm : 0.0129942
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.848448
Tiefenbach Hall A energy : 6063.88
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 6077.87
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.51674e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.618799
HacL_HPE1313A:0_Ch58 : -0.24707
HacL_HPE1313A:0_Ch55 : 23.3887
HacL_HPE1313A:0_Ch54 : 0.0864258
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.025
HacR_HPE1313A:0_Ch58 : -0.603027
HacR_HPE1313A:0_Ch55 : 22.3145
HacR_HPE1313A:0_Ch54 : -0.899414
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202547
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 16.7834
pressure fill bottle H2 : 17.0184
pressure ballast H2 : 17.1237
pressure exhaust H2 : 17.3449
cryogen input temp : 297
crogen return flow : 0
JT valve setting : -0.732422
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13719 -d '2009-11-03 18:55:07' -t 3202547 -s IN