• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 01:01:11 on November 4, 2009

    Entry number 297338

    keyword=Start_Parity_Run_13725__CODA_Config=Pvdis_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=check injector BPMs, try to do pita scan,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 13725 at Wed Nov  4 01:00:59 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20820
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1724.8
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 65
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.8
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.681
    Gun2: PC (PITA) NEG                      : 6.019
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.78022
    Pockels Cell Voltage NEG                 : 1.56044
    Helicity Delay Set                    : 8 cycles
    Helicity Pattern Set                  : Quartet
    Helicity Settle Read                  : 500
    Helicity Delay Read                   : 8 cycles
    Helicity Pattern Read                 : Quartet
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr752mW
    Calculated power in cavity               : 923.916
    Photodiode on table                      : 398.305
    Laser X position on QPD 1                : 112.912
    Laser Y position on QPD 1                : 518.73
    Laser X position on QPD 2                : 20.3495
    Laser Y position on QPD 2                : -606.714
    QPD 1 sum                                : -1.55893
    QPD 2 sum                                : -1.23543
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1520[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2608
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.370506
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.07874
    Fast locking signal sent to laser        : -4.83611
    Calculated polarisation in cavity        : 97.7965
    Photodiode 1 after Wollaston prism       : 72.2169
    Photodiode 2 after Wollaston prism       : 0.804505
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.05
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1529.7
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1432
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -1724.8
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000887143
    Left Arm Q1 gauss meter                  : 0.0002396
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0117331
    Left Arm Q2 momentum                     : 0.00290961
    Left Arm Q2 gauss meter                  : 0.0008299
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.34213
    Left Arm D1 momentum                     : 0.00298472
    Left Arm D1 NMR                          : 0.37937
    Left Arm Q3 power supply current         : 1.38041
    Left Arm Q3 momentum                     : 0.00687011
    Left Arm Q3 gauss meter                  : -0.00060806
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.0534066
    Right Arm Q1 momentum                    : 0.000646872
    Right Arm Q1 gauss meter                 : -4.15e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0121385
    Right Arm Q2 momentum                    : -2.83855e-05
    Right Arm Q2 gauss meter                 : 0.0001964
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.88787
    Right Arm D1 momentum                    : 0.00309596
    Right Arm D1 NMR                         : 0.340712
    Right Arm Q3 power supply current        : -0.00752865
    Right Arm Q3 momentum                    : -1.89206e-05
    Right Arm Q3 gauss meter                 : 5.28e-05
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : -1.2207
    Left Arm Bottom VDC Current              : 2.63672
    Right Arm Top VDC Current                : -18.1641
    Right Arm Bottom VDC Current             : -2.24609
    Left Arm Top VDC voltage                 : 3.99219
    Left Arm Bottom VDC voltage              : 4.00049
    Right Arm Top VDC voltage                : 4
    Right Arm Bottom VDC voltage             : 4.01416
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 4.75635
    Current on Unser monitor                 : 23.0235
    Current on Upstream bcm                  : 4.63385
    Current on Downstream bcm                : 4.87885
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 4.80646
    Tiefenbach Hall A energy                 : 6064.24
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0
    MBSY1c Hall A Beam energy                : 6077.87
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.191
    MBSY1c Bdl                               : 1.51674e+06
    IPM1C12.XPOS                             : -0.458664
    IPM1C12.YPOS                             : 0.196665
    IPM1H04A.XPOS                            : 0.974235
    IPM1H04A.YPOS                            : -0.476968
    IPM1H04B.XPOS                            : -0.462426
    IPM1H04B.YPOS                            : -0.0389587
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.387274
    Survey Y offset bpm12                     : 0.19808
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.61875
    HacL_HPE1313A:0_Ch58                     : -0.245117
    HacL_HPE1313A:0_Ch55                     : 23.0957
    HacL_HPE1313A:0_Ch54                     : 0.0830078
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0591797
    HacR_HPE1313A:0_Ch58                     : -0.605957
    HacR_HPE1313A:0_Ch55                     : 22.2656
    HacR_HPE1313A:0_Ch54                     : -0.900391
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 3202547
    temperature loop 3-1                      : 99.99
    temperature loop 3-2                      : 99.99
    temperature loop 3-3                      : 29.99
    pressure fill target H2                   : 16.7773
    pressure fill bottle H2                   : 17.0214
    pressure ballast H2                       : 16.5911
    pressure exhaust H2                       : 17.3861
    cryogen input temp                        : 296.9
    crogen return flow                        : 0
     JT valve setting                         : -0.390625
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13725 -d '2009-11-04 01:00:44' -t 3202547 -s OUT