User name apar
Log entry time 01:20:35 on November 4, 2009
Entry number 297341
keyword=Start_Parity_Run_13726__CODA_Config=Pvdis_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=check injector BPMs, try to do pita scan,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13726 at Wed Nov 4 01:20:23 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20820
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 65
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.8
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 9.681
Gun2: PC (PITA) NEG : 5.019
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.77045
Pockels Cell Voltage NEG : 1.57021
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 822.365
Photodiode on table : 390.578
Laser X position on QPD 1 : 120.391
Laser Y position on QPD 1 : 513.834
Laser X position on QPD 2 : 18.1825
Laser Y position on QPD 2 : -604.152
QPD 1 sum : -1.54306
QPD 2 sum : -1.20735
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1999
Polarisation in cavity : LEFT
Reflection photodiode : 0.37661
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.111701
Fast locking signal sent to laser : 8.38125
Calculated polarisation in cavity : 98.1145
Photodiode 1 after Wollaston prism : 0.612744
Photodiode 2 after Wollaston prism : 64.3833
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1530.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1432
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1724.8
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.00103265
Left Arm Q1 gauss meter : 0.0002524
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.011632
Left Arm Q2 momentum : 0.00289905
Left Arm Q2 gauss meter : 0.0008111
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.33922
Left Arm D1 momentum : 0.00300392
Left Arm D1 NMR : 0.242385
Left Arm Q3 power supply current : 1.37925
Left Arm Q3 momentum : 0.00681747
Left Arm Q3 gauss meter : -0.00059754
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.0534066
Right Arm Q1 momentum : 0.000959703
Right Arm Q1 gauss meter : -4.76e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0119426
Right Arm Q2 momentum : -2.93907e-05
Right Arm Q2 gauss meter : 0.0001999
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.88668
Right Arm D1 momentum : 0.00307961
Right Arm D1 NMR : 0.419578
Right Arm Q3 power supply current : -0.00663194
Right Arm Q3 momentum : -1.6667e-05
Right Arm Q3 gauss meter : 5.37e-05
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 0.341797
Left Arm Bottom VDC Current : 4.54102
Right Arm Top VDC Current : 24.3652
Right Arm Bottom VDC Current : -3.41797
Left Arm Top VDC voltage : 3.99512
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 3.99805
Right Arm Bottom VDC voltage : 4.00684
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 4.50766
Current on Unser monitor : 22.7255
Current on Upstream bcm : 4.37942
Current on Downstream bcm : 4.63591
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 4.56957
Tiefenbach Hall A energy : 6064.09
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 1.50963
MBSY1c Hall A Beam energy : 6077.87
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.191
MBSY1c Bdl : 1.51674e+06
IPM1C12.XPOS : -0.446891
IPM1C12.YPOS : 0.166773
IPM1H04A.XPOS : 0.974423
IPM1H04A.YPOS : -2.36122
IPM1H04B.XPOS : -0.507566
IPM1H04B.YPOS : -2.45891
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.446891
Survey Y offset bpm12 : 0.166773
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.61875
HacL_HPE1313A:0_Ch58 : -0.245605
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.0830078
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.025
HacR_HPE1313A:0_Ch58 : -0.606445
HacR_HPE1313A:0_Ch55 : 22.168
HacR_HPE1313A:0_Ch54 : -0.899902
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202547
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 16.733
pressure fill bottle H2 : 16.9772
pressure ballast H2 : 16.91
pressure exhaust H2 : 17.3648
cryogen input temp : 296.9
crogen return flow : 0
JT valve setting : -0.244141
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13726 -d '2009-11-04 01:20:14' -t 3202547 -s OUT