User name apar
Log entry time 07:33:59 on November 4, 2009
Entry number 297351
keyword=Start_Parity_Run_13727__CODA_Config=Pvdis_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=Run during Moller,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
Beginning-of-Parity-run EPICS data for Run Number 13727 at Wed Nov 4 07:33:46 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 20837
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 65
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.28
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.681
Gun2: PC (PITA) NEG : 6.019
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.68498
Pockels Cell Voltage NEG : 1.59219
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 0.141576
Photodiode on table : 399.302
Laser X position on QPD 1 : 110.66
Laser Y position on QPD 1 : 517.242
Laser X position on QPD 2 : 21.7169
Laser Y position on QPD 2 : -599.555
QPD 1 sum : -1.60044
QPD 2 sum : -1.26106
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1962
Polarisation in cavity : RIGHT
Reflection photodiode : 0.866142
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 6.39626
Calculated polarisation in cavity : 19.7391
Photodiode 1 after Wollaston prism : 0.00682731
Photodiode 2 after Wollaston prism : 0.00457633
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Feedback info
-----------------------------------------
Parity DAQ Feedback Control(1=on) : 0
-----------------------------------------
LUMI HV info
-----------------------------------------
-----------------------------------------
Detector HV info
-----------------------------------------
HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9 : -1530.4
S0 Front End, HV - Left Slot7 Card2 Ch9 : -1432
S0 Back End, HV - Left Slot7 Card2 Ch9 : -1724.8
-----------------------------------------
General Info
-----------------------------------------
Left Arm arm angle : -0.179
Right Arm arm angle : 0.197
-----------------------------------------
Magnet Info
-----------------------------------------
Left Arm Q1 power supply current : 0
Left Arm Q1 momentum : 0.000827688
Left Arm Q1 gauss meter : 0.0002456
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0117031
Left Arm Q2 momentum : 0.00292808
Left Arm Q2 gauss meter : 0.0008406
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.3501
Left Arm D1 momentum : 0.00293628
Left Arm D1 NMR : 0.213537
Left Arm Q3 power supply current : 1.38026
Left Arm Q3 momentum : 0.00689022
Left Arm Q3 gauss meter : -0.00060801
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 power supply current : 0.0534066
Right Arm Q1 momentum : 0.00113998
Right Arm Q1 gauss meter : -5.11e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : -0.0120757
Right Arm Q2 momentum : -2.8059e-05
Right Arm Q2 gauss meter : 0.0002005
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 1.89006
Right Arm D1 momentum : 0.00301692
Right Arm D1 NMR : 0.168961
Right Arm Q3 power supply current : -0.00603787
Right Arm Q3 momentum : -1.5174e-05
Right Arm Q3 gauss meter : 5.32e-05
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
VDC Currents
-----------------------------------------
Left Arm Top VDC Current : 5.66406
Left Arm Bottom VDC Current : 4.93164
Right Arm Top VDC Current : 23.4375
Right Arm Bottom VDC Current : -1.2207
Left Arm Top VDC voltage : 3.99512
Left Arm Bottom VDC voltage : 4.00049
Right Arm Top VDC voltage : 4.00049
Right Arm Bottom VDC voltage : 4.00098
-----------------------------------------
Beam Info
-----------------------------------------
Average current of the two cavities : 0.0274892
Current on Unser monitor : 17.771
Current on Upstream bcm : 0.0410832
Current on Downstream bcm : 0.0139858
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00543783
Tiefenbach Hall A energy : 6063.88
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 2.24735
MBSY1c Hall A Beam energy : 6077.87
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.191
MBSY1c Bdl : 1.51674e+06
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
ARC stuff
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.618701
HacL_HPE1313A:0_Ch58 : -0.244141
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.081543
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Right Arm Collimator : 0.025293
HacR_HPE1313A:0_Ch58 : -0.606934
HacR_HPE1313A:0_Ch55 : 22.2656
HacR_HPE1313A:0_Ch54 : -0.900879
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----------------------------------------
OTR BEAM INFO
-----------------------------------------
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
fan frequency loop 3 : 0
Encoder position : 3202547
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 16.8093
pressure fill bottle H2 : 16.9406
pressure ballast H2 : 16.9284
pressure exhaust H2 : 17.3587
cryogen input temp : 296.7
crogen return flow : 0
JT valve setting : -0.488281
-----------------------------------------
#
# command to log run in database (should already have been done)\n
/adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13727 -d '2009-11-04 07:33:31' -t 3202547 -s OUT