    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 12:32:35 on November 4, 2009

    Entry number 297368

    keyword=Start_Parity_Run_13728__CODA_Config=Pvdis_Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=off,comment_text=test run ,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=Empty
    Beginning-of-Parity-run EPICS data for Run Number 13728 at Wed Nov  4 12:32:16 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20837
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1724.8
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 65
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.28
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.681
    Gun2: PC (PITA) NEG                      : 6.019
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.75336
    Pockels Cell Voltage NEG                 : 1.54823
    Helicity Delay Set                    : 8 cycles
    Helicity Pattern Set                  : Quartet
    Helicity Settle Read                  : 500
    Helicity Delay Read                   : 8 cycles
    Helicity Pattern Read                 : Quartet
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr736mW
    Calculated power in cavity               : 3.24976
    Photodiode on table                      : 394.566
    Laser X position on QPD 1                : 118.601
    Laser Y position on QPD 1                : 514.855
    Laser X position on QPD 2                : 18.7472
    Laser Y position on QPD 2                : -601.858
    QPD 1 sum                                : -1.60288
    QPD 2 sum                                : -1.2281
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1520[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2045
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.83196
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.155649
    Fast locking signal sent to laser        : 8.96722
    Calculated polarisation in cavity        : 25.0775
    Photodiode 1 after Wollaston prism       : 0.00720214
    Photodiode 2 after Wollaston prism       : 0.00457633
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.05
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Feedback info
    -----------------------------------------
    Parity DAQ Feedback Control(1=on)        : 0
    -----------------------------------------
    LUMI HV info
    -----------------------------------------
    -----------------------------------------
    Detector HV info
    -----------------------------------------
    HAPPEX Det, left arm HV - Left Slot7 Card2 Ch9     : -1530.4
    S0 Front End, HV - Left Slot7 Card2 Ch9    : -1432
    S0 Back End, HV - Left Slot7 Card2 Ch9  : -1724.8
    -----------------------------------------
    General Info
    -----------------------------------------
    Left Arm arm angle                       : -0.179
    Right Arm arm angle                      : 0.197
    -----------------------------------------
    Magnet Info
    -----------------------------------------
    Left Arm Q1 power supply current         : 0
    Left Arm Q1 momentum                     : 0.000743198
    Left Arm Q1 gauss meter                  : 0.0002615
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 0.0106885
    Left Arm Q2 momentum                     : 0.00285199
    Left Arm Q2 gauss meter                  : 0.0008004
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -1.33992
    Left Arm D1 momentum                     : 0.00291596
    Left Arm D1 NMR                          : 0.191418
    Left Arm Q3 power supply current         : 1.37978
    Left Arm Q3 momentum                     : 0.00683128
    Left Arm Q3 gauss meter                  : -0.0006003
    Left Arm Q3 power supply polarity        : disabled
    Right Arm Q1 power supply current        : 0.0534066
    Right Arm Q1 momentum                    : 0.000848356
    Right Arm Q1 gauss meter                 : -4.47e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.0126155
    Right Arm Q2 momentum                    : -3.05849e-05
    Right Arm Q2 gauss meter                 : 0.0001998
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 1.88534
    Right Arm D1 momentum                    : 0.00305126
    Right Arm D1 NMR                         : 0.177505
    Right Arm Q3 power supply current        : -0.00746514
    Right Arm Q3 momentum                    : -1.87609e-05
    Right Arm Q3 gauss meter                 : 5.11e-05
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    VDC Currents
    -----------------------------------------
    Left Arm Top VDC Current                 : 4.24805
    Left Arm Bottom VDC Current              : 3.80859
    Right Arm Top VDC Current                : -28.2715
    Right Arm Bottom VDC Current             : -3.17383
    Left Arm Top VDC voltage                 : 3.99707
    Left Arm Bottom VDC voltage              : 4.00049
    Right Arm Top VDC voltage                : 3.99805
    Right Arm Bottom VDC voltage             : 4.02637
    -----------------------------------------
    Beam Info
    -----------------------------------------
    Average current of the two cavities      : 0.0268517
    Current on Unser monitor                 : 17.1392
    Current on Upstream bcm                  : 0.039831
    Current on Downstream bcm                : 0.0138725
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.0211532
    Tiefenbach Hall A energy                 : 6063.88
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 3.20286
    MBSY1c Hall A Beam energy                : 6077.87
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 1.51674e+06
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    ARC stuff
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Left Arm Collimator                      : 0.618799
    HacL_HPE1313A:0_Ch58                     : -0.240234
    HacL_HPE1313A:0_Ch55                     : 22.998
    HacL_HPE1313A:0_Ch54                     : 0.0810547
    Left Arm Angle Floor Angle               : 0
    Left Arm Angle Vernier                   : 0
    Left Arm Scattering Angle                : -0.179
    Right Arm Collimator                     : 0.0250488
    HacR_HPE1313A:0_Ch58                     : -0.594238
    HacR_HPE1313A:0_Ch55                     : 22.168
    HacR_HPE1313A:0_Ch54                     : -0.909668
    Right Arm Angle Floor Angle              : 0
    Right Arm Angle Vernier                  : 0
    Right Arm Scattering Angle               : 0.197
    -----------------------------------------
    OTR BEAM INFO
    -----------------------------------------
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    fan frequency loop 3                     : 0
    Encoder position                         : 3202547
    temperature loop 3-1                      : 99.99
    temperature loop 3-2                      : 99.99
    temperature loop 3-3                      : 29.99
    pressure fill target H2                   : 25.5695
    pressure fill bottle H2                   : 25.6565
    pressure ballast H2                       : 25.1408
    pressure exhaust H2                       : 26.0365
    cryogen input temp                        : 290.6
    crogen return flow                        : 0
     JT valve setting                         : -0.585938
    -----------------------------------------
    #
    # command to log run in database (should already have been done)\n
    /adaqfs/home/apar/pvdis/runlistDB/addRun2runlist.pl -r 13728 -d '2009-11-04 12:29:36' -t 3202547 -s OUT