• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name D.Wang/X.Deng

    Log entry time 04:10:21 on November 05, 2009

    Entry number 297466

    This entry is a followup to: 297377

    Followups:

    keyword=RHRS Shower ADC problem found

    We took the opportunistic controlled access to check the RHRS shower ADC signals. And found that the ribbon cable for channel 16-31 of one ADC (23rd slot in ROC 1) is unplugged. This explains the missing histograms for shower ADC spectrum. From the database, the correspondence between histograms and the ADC channels is as following:

    histogram number v.s. ADC channel

    16 16

    19 19

    21 21

    23 23

    25 25

    27 27

    30 30

    45 29

    49 18

    51 20

    53 22

    55 24

    57 26

    59 28

    We plugged back in that ribbon cable so from now on we should see those histograms.

    And the reason we don't see histogram 7 is simply because this channel is empty.

    The reason why we don't see histogram 34 is not understood yet. It may be due to a bad channel. We'll check later.



    A copy of this log entry has been emailed to: vasulk, rsubedi, xiaochao, reimer