• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 07:02:22 on November 6, 2009

    Entry number 297757

    keyword=End_of_Parity_Run_13762__CODA_Config=Pvdis
    ************************************************
     Run Number: 13762
     End of Run Comment:
    
    Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=boiling test, raster size 6x6 (mcc unit), @10uA, LD2 target,fan speed 60Hz,junk,dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=0,target_type=20cm LH2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13762 at Fri Nov  6 07:02:12 EST 2009
    CODA Configuration: Pvdis
    
    
    
    Compton Run Number                       : 20860
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1724.8
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 64
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.58
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.681
    Gun2: PC (PITA) NEG                      : 6.019
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.98291
    Pockels Cell Voltage NEG                 : 1.83883
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 739.219
    Photodiode on table                      : 382.602
    Laser X position on QPD 1                : 117.119
    Laser Y position on QPD 1                : 516.85
    Laser X position on QPD 2                : 19.5033
    Laser Y position on QPD 2                : -607.206
    QPD 1 sum                                : -1.54917
    QPD 2 sum                                : -1.18049
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1520[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1752
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.412012
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.452298
    Fast locking signal sent to laser        : 7.73668
    Calculated polarisation in cavity        : 98.1229
    Photodiode 1 after Wollaston prism       : 0.548353
    Photodiode 2 after Wollaston prism       : 57.8763
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.05
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.75
    Left Arm Q1 momentum                     : 3.66029
    Left Arm Q1 gauss meter                  : -0.23214
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.84
    Left Arm Q2 momentum                     : 3.65964
    Left Arm Q2 gauss meter                  : 0.8273
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.22
    Left Arm D1 momentum                     : 3.66004
    Left Arm D1 NMR                          : 1.35576
    Left Arm Q3 power supply current         : 1457.22
    Left Arm Q3 momentum                     : 3.66026
    Left Arm Q3 gauss meter                  : -0.73462
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 0.0534066
    Right Arm Q1 momentum                    : 0.000874868
    Right Arm Q1 gauss meter                 : -4.33e-05
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -6.28557e-05
    Right Arm Q2 momentum                    : 0.00196367
    Right Arm Q2 gauss meter                 : 0.0004284
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 2.51488
    Right Arm D1 momentum                    : 0.0281961
    Right Arm D1 NMR                         : 0.676655
    Right Arm Q3 power supply current        : -0.00554468
    Right Arm Q3 momentum                    : -1.39345e-05
    Right Arm Q3 gauss meter                 : 4.58e-05
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 10.4659
    Current on Unser monitor                 : 27.8627
    Current on Upstream bcm                  : 10.1809
    Current on Downstream bcm                : 10.7509
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 10.513
    Tiefenbach Hall A energy                 : 6067.64
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.0548553
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.00466236
    IPM1C12.YPOS                             : 0.178703
    IPM1H04A.XPOS                            : -0.0912038
    IPM1H04A.YPOS                            : 2.19377
    IPM1H04B.XPOS                            : -0.388878
    IPM1H04B.YPOS                            : 2.50463
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.00106117
    Survey Y offset bpm12                     : 0.196262
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077688
    fan frequency loop 1                     : 59.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.03
    temperature loop 1-2                     : 21.99
    temperature loop 1-3                     : 22.32
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.6291
    pressure fill bottle H2                  : 25.5573
    pressure ballast H2                      : 25.7984
    pressure exhaust H2                      : 24.9058
    cryogen input temp                       : 219.7
    crogen return flow                       : 0
     JT valve setting                        : -0.537109
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 0
    No HAPPEX feedback runlog entry for Run #13762
      Was feedback on?