    User name R. Subedi

    Log entry time 17:46:17 on November 06, 2009

    Entry number 297868

    keyword=RHRS shower channels and T2 trigger

    I fixed T2 trigger in RHRS; all triggers should be fine now.

    I saw in shower stack's PMT location and found that PMT #56 was connected
    by a cable for PMT #8's signal cable (PMT #56's cable being
    disconnected). I restored their proper cables. I saw signal from both of
    these PMTs with their own signal cables. Currently the cable responsible
    for PMT #8 is just hanging around PVDIS rack, it will be connected in the
    next access. I also found that the signal from PMT #19 was missing. After
    replacing its signal cable I saw signal on the scope. Vince found one of
    the shower ribbon cable not connected (wrong cable connrected instead).
    Now all shower signals should be visible in histograms.