User name D.Wang
Log entry time 02:00:44 on November 07, 2009
Entry number 297975
This entry is a followup to: 297956
keyword=LHRS DAQ problem persists
We asked for an escorted access trying to fix the LHRS DAQ problem. I
checked the gate signal from the TM module on the scope and didn't see
any signal. Then I found there was nothing plugged in the L1A of the TM
module. There was an ECL cable labled with "1 DAQ L1A" lying on the
floor, both ends unplugged. I tired taking an L1A copy from the delay
module and plugging it into the TM module, but it didn't fix the problem,
maybe because it's not well timed. Then I gave up due to limited time. We
need to fix it during next access.