Log entry time 04:02:19 on November 7, 2009
Entry number 298000
keyword=End_of_Parity_Run_13777__CODA_Config=Pvdis
************************************************
Run Number: 13777
End of Run Comment:
Run_type=Test,beam_energy=3.4839,beam_polarization=87,beam_raster=on,comment_text=boiling test, @85uA, LD2 target, fan speed 50Hz, raster size 6x6 (mcc unit),dithering_magnet=off,dithering_magnets=,leftarm_p=pi,leftarm_theta=14,parity_feedback=off,parity_ihwp=out,rightarm_p=pi,rightarm_theta=14,target_fanspeed=60,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 13777 at Sat Nov 7 04:02:07 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20887
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 112
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.681
Gun2: PC (PITA) NEG : 7.019
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2
Pockels Cell Voltage NEG : 1.84371
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 0.506298
Photodiode on table : 391.825
Laser X position on QPD 1 : 112.835
Laser Y position on QPD 1 : 522.618
Laser X position on QPD 2 : 19.896
Laser Y position on QPD 2 : -608.688
QPD 1 sum : -1.56626
QPD 2 sum : -1.21101
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2072
Polarisation in cavity : LEFT
Reflection photodiode : 0.850272
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.151987
Fast locking signal sent to laser : 9.11005
Calculated polarisation in cavity : 17.1764
Photodiode 1 after Wollaston prism : 0.0222222
Photodiode 2 after Wollaston prism : 0.0157073
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.75
Left Arm Q1 momentum : 3.66029
Left Arm Q1 gauss meter : -0.23215
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.84
Left Arm Q2 momentum : 3.65963
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.22
Left Arm D1 momentum : 3.66008
Left Arm D1 NMR : 1.35577
Left Arm Q3 power supply current : 1457.2
Left Arm Q3 momentum : 3.66022
Left Arm Q3 gauss meter : -0.73457
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.33
Right Arm Q1 momentum : 2.62958
Right Arm Q1 gauss meter : -0.0491
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1132.11
Right Arm Q2 momentum : 2.63057
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.84
Right Arm D1 momentum : 2.62998
Right Arm D1 NMR : 0.975952
Right Arm Q3 power supply current : 1046.63
Right Arm Q3 momentum : 2.63033
Right Arm Q3 gauss meter : 0.4683
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 84.8372
Current on Unser monitor : 102.178
Current on Upstream bcm : 82.7533
Current on Downstream bcm : 86.9211
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 85.6581
Tiefenbach Hall A energy : 6067.37
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0548678
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0171533
IPM1C12.YPOS : 0.189658
IPM1H04A.XPOS : -2.8876
IPM1H04A.YPOS : 1.99796
IPM1H04B.XPOS : -2.98661
IPM1H04B.YPOS : 2.03131
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.0171533
Survey Y offset bpm12 : 0.185637
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 38
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.01
temperature loop 1-2 : 21.97
temperature loop 1-3 : 22.64
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.6245
pressure fill bottle H2 : 25.7404
pressure ballast H2 : 25.9373
pressure exhaust H2 : 25.9754
cryogen input temp : 219.2
crogen return flow : 0
JT valve setting : -0.0488281
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 0
No HAPPEX feedback runlog entry for Run #13777
Was feedback on?