• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name V. Sulkosky

    Log entry time 13:51:57 on November 08, 2009

    Entry number 298344

    This entry is a followup to: 298338

    keyword=L-HRS Pion Rejector Quality Plots

    I have modified the pion rejector database files to make all
    the block coefficients the same (1.). Figures 1 shows layer 1
    versus layer 2 plots for all events, electrons (GC > 300) and
    pions (GC < 10).

    Figure 2 shows the energy in the pion rejector divided by the
    spectrometer momentum, again for all events, electrons and pions.

    I have updated the online displays to show these plots.

    One could shift the E/P spectrum to 1 by multiplying by ~ 1.78.

    A copy of this log entry has been emailed to: reimer,xiaochao,rsubedi,jinhuang



    PR Layer 1 vs PR Layer 2 Energy



    Energy over Momentum