• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 17:06:51 on November 8, 2009

    Entry number 298370

    keyword=End_of_Parity_Run_13822__CODA_Config=Pvdis
    ************************************************
     Run Number: 13822
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=test for synch signal,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13822 at Sun Nov  8 17:06:40 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20906
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1724.8
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 60
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.3
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.2
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.681
    Gun2: PC (PITA) NEG                      : 7.019
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.7558
    Pockels Cell Voltage NEG                 : 1.54579
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr730mW
    Calculated power in cavity               : 705.711
    Photodiode on table                      : 381.356
    Laser X position on QPD 1                : 115.156
    Laser Y position on QPD 1                : 518.469
    Laser X position on QPD 2                : 19.7277
    Laser Y position on QPD 2                : -607.078
    QPD 1 sum                                : -1.50278
    QPD 2 sum                                : -1.16828
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1520[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -1420[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2040
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.44009
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 6.31936
    Fast locking signal sent to laser        : 5.91284
    Calculated polarisation in cavity        : 98.0707
    Photodiode 1 after Wollaston prism       : 0.538046
    Photodiode 2 after Wollaston prism       : 54.9231
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.05
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.75
    Left Arm Q1 momentum                     : 3.66029
    Left Arm Q1 gauss meter                  : -0.23211
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.81
    Left Arm Q2 momentum                     : 3.65957
    Left Arm Q2 gauss meter                  : 0.8271
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : -0.00251642
    Left Arm D1 momentum                     : 0.000161178
    Left Arm D1 NMR                          : 1.17562
    Left Arm Q3 power supply current         : 1457.19
    Left Arm Q3 momentum                     : 3.6602
    Left Arm Q3 gauss meter                  : -0.73454
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.49
    Right Arm Q1 momentum                    : 2.62986
    Right Arm Q1 gauss meter                 : -0.04911
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1132.07
    Right Arm Q2 momentum                    : 2.63047
    Right Arm Q2 gauss meter                 : 0.5924
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.649
    Right Arm D1 momentum                    : 2.63002
    Right Arm D1 NMR                         : 0.975967
    Right Arm Q3 power supply current        : 1046.29
    Right Arm Q3 momentum                    : 2.62948
    Right Arm Q3 gauss meter                 : 0.4678
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0321088
    Current on Unser monitor                 : 17.3611
    Current on Upstream bcm                  : 0.0393231
    Current on Downstream bcm                : 0.0248945
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.142602
    Tiefenbach Hall A energy                 : 6067.46
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.761379
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 0.0377197
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Empty
    Encoder position                         : 3202553
    fan frequency loop 1                     : 60
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.02
    temperature loop 1-2                     : 21.97
    temperature loop 1-3                     : 22.3
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.4597
    pressure fill bottle H2                  : 25.6123
    pressure ballast H2                      : 25.5772
    pressure exhaust H2                      : 24.4907
    cryogen input temp                       : 219
    crogen return flow                       : 0.42317
     JT valve setting                        : -0.634766
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 0
    No HAPPEX feedback runlog entry for Run #13822
      Was feedback on?