User name Jin Huang
Log entry time 23:40:36 on November 08, 2009
Entry number 298453
keyword=Bull's eye scan : Final Segment
Bull's eye scan
Scan BPM positions to calibrate ADC BPM readings VS EPICS BPM
readings
- 5uA beam on empty target
- raster off
- taking 1kHz T8 on both L/R DAQs
- 5min run each rnu, ~300k triggers
- MCC have difficulty move BPM A X to a lower value than -3mm
- Norminal beam position are BPM A = B = (-3.0
2.0)
- continue from what's left over from Vince
Scan Log
- One run at the nominal beam center . Done by Vince
- One run at (x,y) of both BPM A and B at (+3.0, +3.0).
Done by Vince
- One run at (x,y) of both BPM A and B at (+3.0, -3.0).
Done by Vince
- One run at (x,y) of both BPM A and B at (-3.0, -3.0):
BPM A = (-3.0
-1.0); B = (-6.0
-1.0): 25336/4876
- One run at (x,y) of both BPM A and B at (-3.0, +3.0):
BPM A = (-3.0 5.0); B =
(-6.0 5.0): 25337/4877
- One reference run at the nominal beam center, collaborate
HRS test runs, taking
T1 instead of T8 @ 5uA carbon target: BPM A
= B = (-3.0 2.0)
: 25339/4879
- End of Bull's eye scan