NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 00:19:49 on November 10, 2009
Entry number 298672
keyword=End_of_Parity_Run_13859__CODA_Config=Pvdis
************************************************
Run Number: 13859
End of Run Comment:
Run_type=Test,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=off,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 13859 at Tue Nov 10 00:19:41 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20911
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 101
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.755
Gun2: PC (PITA) NEG : 6.945
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.70452
Pockels Cell Voltage NEG : 1.53114
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 779.275
Photodiode on table : 386.59
Laser X position on QPD 1 : 113.676
Laser Y position on QPD 1 : 518.938
Laser X position on QPD 2 : 19.3631
Laser Y position on QPD 2 : -608.293
QPD 1 sum : -1.51987
QPD 2 sum : -1.18904
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2338
Polarisation in cavity : LEFT
Reflection photodiode : 0.407129
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : -0.679363
Fast locking signal sent to laser : 7.11408
Calculated polarisation in cavity : 98.0567
Photodiode 1 after Wollaston prism : 0.598447
Photodiode 2 after Wollaston prism : 60.9963
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2754.12
Left Arm Q1 momentum : 3.66086
Left Arm Q1 gauss meter : -0.23218
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.82
Left Arm Q2 momentum : 3.65959
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.00335285
Left Arm D1 momentum : 0.000423962
Left Arm D1 NMR : 1.90034
Left Arm Q3 power supply current : 1457.2
Left Arm Q3 momentum : 3.66021
Left Arm Q3 gauss meter : -0.73455
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.65
Right Arm Q1 momentum : 2.63008
Right Arm Q1 gauss meter :
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1132.08
Right Arm Q2 momentum : 2.6305
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.954
Right Arm D1 momentum : 2.63
Right Arm D1 NMR : 0.975962
Right Arm Q3 power supply current : 1046.45
Right Arm Q3 momentum : 2.62987
Right Arm Q3 gauss meter : 0.4682
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 51.399
Current on Unser monitor : 67.8542
Current on Upstream bcm : 49.9394
Current on Downstream bcm : 52.8585
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 51.4954
Tiefenbach Hall A energy : 6067.39
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0548187
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.00126761
IPM1C12.YPOS : 0.189895
IPM1H04A.XPOS : 0.074818
IPM1H04A.YPOS : -0.107911
IPM1H04B.XPOS : 0.0174105
IPM1H04B.YPOS : -0.02209
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.00126761
Survey Y offset bpm12 : 0.189895
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.09
temperature loop 1-2 : 21.98
temperature loop 1-3 : 22.43
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.6443
pressure fill bottle H2 : 26.0456
pressure ballast H2 : 25.6657
pressure exhaust H2 : 25.8961
cryogen input temp : 218
crogen return flow : 0.44635
JT valve setting : -0.634766
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_13859.log:
Cumulative stats for 17570 events:
Events failing cut conditions:
0 Low_beam 16412
1 Beam_burp 28
2 Evt_seq 0
3 Pair_seq 163
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------