User name apar
Log entry time 04:46:16 on November 10, 2009
Entry number 298713
keyword=End_of_Parity_Run_13863__CODA_Config=Pvdis
************************************************
Run Number: 13863
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=off,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 13863 at Tue Nov 10 04:46:09 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 20912
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1724.8
Wien field : 49.796
Laser attenuation Hall A : 121
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.744
Gun2: PC (PITA) NEG : 6.956
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75092
Pockels Cell Voltage NEG : 1.55067
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr736mW
Calculated power in cavity : 0.48782
Photodiode on table : 386.59
Laser X position on QPD 1 : 114.751
Laser Y position on QPD 1 : 517.579
Laser X position on QPD 2 : 19.9362
Laser Y position on QPD 2 : -602.932
QPD 1 sum : -1.55283
QPD 2 sum : -1.20857
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -1420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.2599
Polarisation in cavity : LEFT
Reflection photodiode : 0.872246
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -5.74437
Calculated polarisation in cavity : 15.9646
Photodiode 1 after Wollaston prism : 0.0221687
Photodiode 2 after Wollaston prism : 0.0160648
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2754.07
Left Arm Q1 momentum : 3.66071
Left Arm Q1 gauss meter : -0.23217
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.8
Left Arm Q2 momentum : 3.65956
Left Arm Q2 gauss meter : 0.8272
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.0033171
Left Arm D1 momentum : 0.000365226
Left Arm D1 NMR : 1.21084
Left Arm Q3 power supply current : 1457.19
Left Arm Q3 momentum : 3.66019
Left Arm Q3 gauss meter : -0.73459
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.65
Right Arm Q1 momentum : 2.63
Right Arm Q1 gauss meter : -0.04914
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1132.09
Right Arm Q2 momentum : 2.63052
Right Arm Q2 gauss meter : 0.5924
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.954
Right Arm D1 momentum : 2.63002
Right Arm D1 NMR : 0.975968
Right Arm Q3 power supply current : 1046.44
Right Arm Q3 momentum : 2.62986
Right Arm Q3 gauss meter : 0.4682
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 89.6539
Current on Unser monitor : 106.346
Current on Upstream bcm : 87.3507
Current on Downstream bcm : 91.7742
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 90.0054
Tiefenbach Hall A energy : 6067.37
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.0548274
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.000537217
IPM1C12.YPOS : 0.164188
IPM1H04A.XPOS : -0.165801
IPM1H04A.YPOS : -0.109722
IPM1H04B.XPOS : -8.11219e-05
IPM1H04B.YPOS : -0.00438559
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.000537217
Survey Y offset bpm12 : 0.164188
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.13
temperature loop 1-2 : 22
temperature loop 1-3 : 22.56
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.8244
pressure fill bottle H2 : 25.9373
pressure ballast H2 : 25.4276
pressure exhaust H2 : 24.8844
cryogen input temp : 218.5
crogen return flow : 0
JT valve setting : -0.292969
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_13863.log:
Cumulative stats for 99749 events:
Events failing cut conditions:
0 Low_beam 5988
1 Beam_burp 59
2 Evt_seq 0
3 Pair_seq 924
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------