Log entry time 07:37:22 on November 12, 2009
Entry number 299148
keyword=End_of_Parity_Run_13892__CODA_Config=Pvdis
************************************************
Run Number: 13892
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production, 2uA test,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 13892 at Thu Nov 12 07:37:16 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20939
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1728.2
Wien field : 49.796
Laser attenuation Hall A : 63
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.97
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.717
Gun2: PC (PITA) NEG : 6.983
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.67766
Pockels Cell Voltage NEG : 1.58242
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr736mW
Calculated power in cavity : 629.489
Photodiode on table : 399.053
Laser X position on QPD 1 : 127.636
Laser Y position on QPD 1 : 507.584
Laser X position on QPD 2 : 16.5428
Laser Y position on QPD 2 : -605.788
QPD 1 sum : -1.67613
QPD 2 sum : -1.26228
Position set point for adjustable
mirror 1 (either x or y) : -1520[c]
Position set point for adjustable
mirror 2 (either x or y) : -640[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1916
Polarisation in cavity : RIGHT
Reflection photodiode : 0.524324
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.928401
Fast locking signal sent to laser : 5.48801
Calculated polarisation in cavity : 97.7155
Photodiode 1 after Wollaston prism : 49.411
Photodiode 2 after Wollaston prism : 0.570921
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.05
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.91
Left Arm Q1 momentum : 3.66043
Left Arm Q1 gauss meter : -0.23212
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.55
Left Arm Q2 momentum : 3.65896
Left Arm Q2 gauss meter : 0.8271
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.21
Left Arm D1 momentum : 3.66009
Left Arm D1 NMR : 1.35578
Left Arm Q3 power supply current : 1456.82
Left Arm Q3 momentum : 3.65927
Left Arm Q3 gauss meter : -0.73414
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.97
Right Arm Q1 momentum : 2.6305
Right Arm Q1 gauss meter : -0.04915
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.71
Right Arm Q2 momentum : 2.62963
Right Arm Q2 gauss meter : 0.5919
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.036
Right Arm D1 momentum : 2.62994
Right Arm D1 NMR : 0.975941
Right Arm Q3 power supply current : 1046.4
Right Arm Q3 momentum : 2.62974
Right Arm Q3 gauss meter : 0.4682
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 2.01689
Current on Unser monitor : 20.3583
Current on Upstream bcm : 1.96464
Current on Downstream bcm : 2.06914
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 2.18437
Tiefenbach Hall A energy : 6067.37
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.630914
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.0269138
IPM1C12.YPOS : 0.190826
IPM1H04A.XPOS : -0.692261
IPM1H04A.YPOS : -0.0586854
IPM1H04B.XPOS : -0.704031
IPM1H04B.YPOS : -0.0333103
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.00755492
Survey Y offset bpm12 : 0.190826
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.15
temperature loop 1-2 : 22
temperature loop 1-3 : 22.32
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.1942
pressure fill bottle H2 : 25.4673
pressure ballast H2 : 24.9104
pressure exhaust H2 : 25.1347
cryogen input temp : 218.4
crogen return flow : 0
JT valve setting : -0.488281
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_13892.log:
Cumulative stats for 20597 events:
Events failing cut conditions:
0 Low_beam 20597
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 190
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------