    Log entry time 15:32:03 on November 13, 2009

    Entry number 299559

    keyword=End_of_Parity_Run_13925__CODA_Config=Pvdis
    ************************************************
     Run Number: 13925
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=100 uA, dithering off,Compton Tunning.,dithering_magnet=off,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=Empty
    ************************************************
    End-of-Parity-run EPICS data for Run Number 13925 at Fri Nov 13 15:31:56 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 20969
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1728.2
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 138
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.9
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.183
    Gun2: PC (PITA) NEG                      : 6.517
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.99512
    Pockels Cell Voltage NEG                 : 1.84371
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr736mW
    Calculated power in cavity               : 623.782
    Photodiode on table                      : 387.338
    Laser X position on QPD 1                : 96.6061
    Laser Y position on QPD 1                : 529.951
    Laser X position on QPD 2                : 24.1388
    Laser Y position on QPD 2                : -608.178
    QPD 1 sum                                : -1.18293
    QPD 2 sum                                : -1.17561
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -3545[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -640[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.1317
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.459623
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.68
    Slow locking signal sent to laser        : 7.70738
    Fast locking signal sent to laser        : -8.16883
    Calculated polarisation in cavity        : 97.4855
    Photodiode 1 after Wollaston prism       : 0.619839
    Photodiode 2 after Wollaston prism       : 48.6807
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.86
    Left Arm Q1 momentum                     : 3.66043
    Left Arm Q1 gauss meter                  : -0.2321
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.53
    Left Arm Q2 momentum                     : 3.65892
    Left Arm Q2 gauss meter                  : 0.827
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.2
    Left Arm D1 momentum                     : 3.66007
    Left Arm D1 NMR                          : 1.35577
    Left Arm Q3 power supply current         : 1456.81
    Left Arm Q3 momentum                     : 3.65923
    Left Arm Q3 gauss meter                  : -0.73426
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.97
    Right Arm Q1 momentum                    : 2.6305
    Right Arm Q1 gauss meter                 : -0.04918
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.7
    Right Arm Q2 momentum                    : 2.62962
    Right Arm Q2 gauss meter                 : 0.5919
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 932.037
    Right Arm D1 momentum                    : 2.62999
    Right Arm D1 NMR                         : 0.975959
    Right Arm Q3 power supply current        : 1046.39
    Right Arm Q3 momentum                    : 2.62972
    Right Arm Q3 gauss meter                 : 0.4682
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 96.9843
    Current on Unser monitor                 : 113.256
    Current on Upstream bcm                  : 95.4894
    Current on Downstream bcm                : 98.4792
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 97.4807
    Tiefenbach Hall A energy                 : 6068.28
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 0.789937
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.37211
    IPM1C12.YPOS                             : 0.161175
    IPM1H04A.XPOS                            : 1.74637
    IPM1H04A.YPOS                            : 0.495652
    IPM1H04B.XPOS                            : 0.0290875
    IPM1H04B.YPOS                            : -0.00102627
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.373956
    Survey Y offset bpm12                     : 0.161799
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Empty
    Encoder position                         : 3202553
    fan frequency loop 1                     : 60
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.28
    temperature loop 1-2                     : 21.99
    temperature loop 1-3                     : 22.33
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.1209
    pressure fill bottle H2                  : 25.4063
    pressure ballast H2                      : 24.9668
    pressure exhaust H2                      : 23.8788
    cryogen input temp                       : 217.8
    crogen return flow                       : 0.442014
     JT valve setting                        : -0.292969
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_13925.log:
    
       Cumulative stats for 25775 events: 
       
       Events failing cut conditions:
       0         Low_beam  25652
       1        Beam_burp     22
       2          Evt_seq      0
       3         Pair_seq    237
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------