Log entry time 15:32:03 on November 13, 2009
Entry number 299559
keyword=End_of_Parity_Run_13925__CODA_Config=Pvdis
************************************************
Run Number: 13925
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=100 uA, dithering off,Compton Tunning.,dithering_magnet=off,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60,target_type=Empty
************************************************
End-of-Parity-run EPICS data for Run Number 13925 at Fri Nov 13 15:31:56 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 20969
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1728.2
Wien field : 49.796
Laser attenuation Hall A : 138
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 4.9
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 8.183
Gun2: PC (PITA) NEG : 6.517
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.99512
Pockels Cell Voltage NEG : 1.84371
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr736mW
Calculated power in cavity : 623.782
Photodiode on table : 387.338
Laser X position on QPD 1 : 96.6061
Laser Y position on QPD 1 : 529.951
Laser X position on QPD 2 : 24.1388
Laser Y position on QPD 2 : -608.178
QPD 1 sum : -1.18293
QPD 2 sum : -1.17561
Position set point for adjustable
mirror 1 (either x or y) : -3545[c]
Position set point for adjustable
mirror 2 (either x or y) : -640[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1317
Polarisation in cavity : LEFT
Reflection photodiode : 0.459623
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.68
Slow locking signal sent to laser : 7.70738
Fast locking signal sent to laser : -8.16883
Calculated polarisation in cavity : 97.4855
Photodiode 1 after Wollaston prism : 0.619839
Photodiode 2 after Wollaston prism : 48.6807
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.86
Left Arm Q1 momentum : 3.66043
Left Arm Q1 gauss meter : -0.2321
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.53
Left Arm Q2 momentum : 3.65892
Left Arm Q2 gauss meter : 0.827
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.2
Left Arm D1 momentum : 3.66007
Left Arm D1 NMR : 1.35577
Left Arm Q3 power supply current : 1456.81
Left Arm Q3 momentum : 3.65923
Left Arm Q3 gauss meter : -0.73426
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.97
Right Arm Q1 momentum : 2.6305
Right Arm Q1 gauss meter : -0.04918
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.7
Right Arm Q2 momentum : 2.62962
Right Arm Q2 gauss meter : 0.5919
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.037
Right Arm D1 momentum : 2.62999
Right Arm D1 NMR : 0.975959
Right Arm Q3 power supply current : 1046.39
Right Arm Q3 momentum : 2.62972
Right Arm Q3 gauss meter : 0.4682
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 96.9843
Current on Unser monitor : 113.256
Current on Upstream bcm : 95.4894
Current on Downstream bcm : 98.4792
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 97.4807
Tiefenbach Hall A energy : 6068.28
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.789937
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p :
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.37211
IPM1C12.YPOS : 0.161175
IPM1H04A.XPOS : 1.74637
IPM1H04A.YPOS : 0.495652
IPM1H04B.XPOS : 0.0290875
IPM1H04B.YPOS : -0.00102627
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.373956
Survey Y offset bpm12 : 0.161799
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : Empty
Encoder position : 3202553
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.28
temperature loop 1-2 : 21.99
temperature loop 1-3 : 22.33
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.1209
pressure fill bottle H2 : 25.4063
pressure ballast H2 : 24.9668
pressure exhaust H2 : 23.8788
cryogen input temp : 217.8
crogen return flow : 0.442014
JT valve setting : -0.292969
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_13925.log:
Cumulative stats for 25775 events:
Events failing cut conditions:
0 Low_beam 25652
1 Beam_burp 22
2 Evt_seq 0
3 Pair_seq 237
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------