NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 20:50:15 on November 14, 2009
Entry number 299904
keyword=End_of_Parity_Run_13958__CODA_Config=Pvdis
************************************************
Run Number: 13958
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=Production,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 13958 at Sat Nov 14 20:50:09 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 20989
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1728.2
Wien field : 49.796
Laser attenuation Hall A : 84
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.3
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.701
Gun2: PC (PITA) NEG : 6.999
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.98535
Pockels Cell Voltage NEG : 1.83639
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr741mW
Calculated power in cavity : 0.22598
Photodiode on table : 392.074
Laser X position on QPD 1 : 98.1615
Laser Y position on QPD 1 : 535.557
Laser X position on QPD 2 : 21.9945
Laser Y position on QPD 2 : -613.456
QPD 1 sum : -1.2635
QPD 2 sum : -1.24153
Position set point for adjustable
mirror 1 (either x or y) : -3545[c]
Position set point for adjustable
mirror 2 (either x or y) : -640[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : 8
+47.2608
Polarisation in cavity : RIGHT
Reflection photodiode : 0.825856
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.68
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 4.77751
Calculated polarisation in cavity : 17.5264
Photodiode 1 after Wollaston prism : 0.0104953
Photodiode 2 after Wollaston prism : 0.00710285
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2753.91
Left Arm Q1 momentum : 3.6605
Left Arm Q1 gauss meter : -0.23208
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.54
Left Arm Q2 momentum : 3.65893
Left Arm Q2 gauss meter : 0.8269
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.21
Left Arm D1 momentum : 3.66007
Left Arm D1 NMR : 1.35577
Left Arm Q3 power supply current : 1456.81
Left Arm Q3 momentum : 3.65923
Left Arm Q3 gauss meter : -0.73428
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.75
Right Arm Q1 momentum : 2.63022
Right Arm Q1 gauss meter : -0.04918
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1131.71
Right Arm Q2 momentum : 2.62964
Right Arm Q2 gauss meter : 0.5919
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 932.036
Right Arm D1 momentum : 2.62999
Right Arm D1 NMR : 0.975957
Right Arm Q3 power supply current : 1046.39
Right Arm Q3 momentum : 2.62973
Right Arm Q3 gauss meter : 0.4681
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 23.5469
Current on Unser monitor : 35.2519
Current on Upstream bcm : 16.3574
Current on Downstream bcm : 30.7363
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 16.7232
Tiefenbach Hall A energy : 6067.62
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 4.17478
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : -0.0690995
IPM1C12.YPOS : 0.12413
IPM1H04A.XPOS : -0.784444
IPM1H04A.YPOS : 0.0762879
IPM1H04B.XPOS : -0.7963
IPM1H04B.YPOS : 0.0553358
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : -0.0690995
Survey Y offset bpm12 : 0.12413
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.6
temperature loop 1-2 : 22
temperature loop 1-3 : 22.37
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.2262
pressure fill bottle H2 : 25.4917
pressure ballast H2 : 25.2064
pressure exhaust H2 : 25.4841
cryogen input temp : 218.1
crogen return flow : 0.48933
JT valve setting : -0.244141
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_13958.log:
Cumulative stats for 99928 events:
Events failing cut conditions:
0 Low_beam 29472
1 Beam_burp 467
2 Evt_seq 0
3 Pair_seq 929
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------