    Log entry time 23:20:07 on November 16, 2009

    Entry number 300439

    keyword=End_of_Parity_Run_14004__CODA_Config=Pvdis
    ************************************************
     Run Number: 14004
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production at low current (2 muA),dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14004 at Mon Nov 16 23:20:01 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 21033
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1728.2
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 60
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.1
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.188
    Gun2: PC (PITA) NEG                      : 6.512
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.7558
    Pockels Cell Voltage NEG                 : 1.54823
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr741mW
    Calculated power in cavity               : 716.372
    Photodiode on table                      : 399.551
    Laser X position on QPD 1                : 93.4705
    Laser Y position on QPD 1                : 534.2
    Laser X position on QPD 2                : 25.0753
    Laser Y position on QPD 2                : -612.901
    QPD 1 sum                                : -1.23421
    QPD 2 sum                                : -1.21712
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -3545[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -640[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2800
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.452298
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.228896
    Fast locking signal sent to laser        : -2.19923
    Calculated polarisation in cavity        : 97.6829
    Photodiode 1 after Wollaston prism       : 55.9625
    Photodiode 2 after Wollaston prism       : 0.655941
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.75
    Left Arm Q1 momentum                     : 3.66029
    Left Arm Q1 gauss meter                  : -0.23207
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.52
    Left Arm Q2 momentum                     : 3.6589
    Left Arm Q2 gauss meter                  : 0.827
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.27
    Left Arm D1 momentum                     : 3.66008
    Left Arm D1 NMR                          : 1.35577
    Left Arm Q3 power supply current         : 1456.78
    Left Arm Q3 momentum                     : 3.65917
    Left Arm Q3 gauss meter                  : -0.73424
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.7
    Right Arm Q1 momentum                    : 2.63022
    Right Arm Q1 gauss meter                 : -0.04916
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.69
    Right Arm Q2 momentum                    : 2.6296
    Right Arm Q2 gauss meter                 : 0.5919
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 932.005
    Right Arm D1 momentum                    : 2.62997
    Right Arm D1 NMR                         : 0.975953
    Right Arm Q3 power supply current        : 1046.38
    Right Arm Q3 momentum                    : 2.6297
    Right Arm Q3 gauss meter                 : 0.4681
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 0.0321309
    Current on Unser monitor                 : 17.9878
    Current on Upstream bcm                  : 0.0395004
    Current on Downstream bcm                : 0.0247614
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 0.129472
    Tiefenbach Hall A energy                 : 6067.46
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 2.13426
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0
    IPM1C12.YPOS                             : 0
    IPM1H04A.XPOS                            : 0
    IPM1H04A.YPOS                            : 0
    IPM1H04B.XPOS                            : 0
    IPM1H04B.YPOS                            : 0
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0
    Survey Y offset bpm12                     : 0
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077690
    fan frequency loop 1                     : 59.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.26
    temperature loop 1-2                     : 21.99
    temperature loop 1-3                     : 22.29
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.4139
    pressure fill bottle H2                  : 25.5039
    pressure ballast H2                      : 25.6275
    pressure exhaust H2                      : 25.5909
    cryogen input temp                       : 218.1
    crogen return flow                       : 0
     JT valve setting                        : -0.634766
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14004.log:
    
       Cumulative stats for 58568 events: 
       
       Events failing cut conditions:
       0         Low_beam  58568
       1        Beam_burp      0
       2          Evt_seq      0
       3         Pair_seq    543
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------