• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 07:29:22 on November 18, 2009

    Entry number 300732

    keyword=End_of_Parity_Run_14030__CODA_Config=Pvdis
    ************************************************
     Run Number: 14030
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=production,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=in,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14030 at Wed Nov 18 07:29:17 EST 2009
    CODA Configuration: Pvdis
    
    
    
    Compton Run Number                       : 21049
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1723.07
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 152
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : IN
    Beam Half-wave plate Read(off=out)       : IN
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.9
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 8.165
    Gun2: PC (PITA) NEG                      : 6.535
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.74847
    Pockels Cell Voltage NEG                 : 1.55067
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr736mW
    Calculated power in cavity               : 858.123
    Photodiode on table                      : 399.801
    Laser X position on QPD 1                : 95.0378
    Laser Y position on QPD 1                : 534.027
    Laser X position on QPD 2                : 23.5757
    Laser Y position on QPD 2                : -614.627
    QPD 1 sum                                : -1.23665
    QPD 2 sum                                : -1.20369
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -3545[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -640[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2594
    Polarisation in cavity                   : RIGHT
    Reflection photodiode                    : 0.465727
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.151987
    Fast locking signal sent to laser        : 6.75151
    Calculated polarisation in cavity        : 97.9518
    Photodiode 1 after Wollaston prism       : 66.7068
    Photodiode 2 after Wollaston prism       : 0.694554
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.96
    Left Arm Q1 momentum                     : 3.66057
    Left Arm Q1 gauss meter                  : -0.23203
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1575.85
    Left Arm Q2 momentum                     : 3.65966
    Left Arm Q2 gauss meter                  : 0.8271
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.34
    Left Arm D1 momentum                     : 3.66004
    Left Arm D1 NMR                          : 1.35576
    Left Arm Q3 power supply current         : 1457.1
    Left Arm Q3 momentum                     : 3.65995
    Left Arm Q3 gauss meter                  : -0.7344
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1978.13
    Right Arm Q1 momentum                    : 2.63079
    Right Arm Q1 gauss meter                 : -0.04916
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : -0.00777562
    Right Arm Q2 momentum                    : -1.70708e-05
    Right Arm Q2 gauss meter                 : 0.0004973
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.522
    Right Arm D1 momentum                    : 2.63008
    Right Arm D1 NMR                         : 0.97599
    Right Arm Q3 power supply current        : 1046.4
    Right Arm Q3 momentum                    : 2.62974
    Right Arm Q3 gauss meter                 : 0.4678
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 79.1426
    Current on Unser monitor                 : 97.0771
    Current on Upstream bcm                  : 77.1094
    Current on Downstream bcm                : 81.1757
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 79.6285
    Tiefenbach Hall A energy                 : 6066.86
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 3.97006
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : 0.348206
    IPM1C12.YPOS                             : 0.244557
    IPM1H04A.XPOS                            : -0.685423
    IPM1H04A.YPOS                            : 0.0958658
    IPM1H04B.XPOS                            : -0.708171
    IPM1H04B.YPOS                            : 0.0412693
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.348206
    Survey Y offset bpm12                     : 0.244557
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077688
    fan frequency loop 1                     : 60
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.41
    temperature loop 1-2                     : 21.99
    temperature loop 1-3                     : 22.51
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.3834
    pressure fill bottle H2                  : 25.565
    pressure ballast H2                      : 25.3574
    pressure exhaust H2                      : 24.5426
    cryogen input temp                       : 218.2
    crogen return flow                       : 0
     JT valve setting                        : -0.390625
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14030.log:
    
       Cumulative stats for 99809 events: 
       
       Events failing cut conditions:
       0         Low_beam  18291
       1        Beam_burp    137
       2          Evt_seq      1
       3         Pair_seq      5
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------