• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name apar

    Log entry time 17:51:32 on November 22, 2009

    Entry number 301885

    keyword=End_of_Parity_Run_14151__CODA_Config=Pvdis
    ************************************************
     Run Number: 14151
     End of Run Comment:
    
    Run_type=Calibration,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=During Q2 measurement,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm Al Dummy
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14151 at Sun Nov 22 17:51:25 EST 2009
    CODA Configuration: Pvdis
    
    # Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
    
    Compton Run Number                       : 21150
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1723.07
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 106
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 5.1
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.611
    Gun2: PC (PITA) NEG                      : 7.089
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 1.76557
    Pockels Cell Voltage NEG                 : 1.55556
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 577.715
    Photodiode on table                      : 386.092
    Laser X position on QPD 1                : 112.237
    Laser Y position on QPD 1                : 515.249
    Laser X position on QPD 2                : 20.1901
    Laser Y position on QPD 2                : -601.094
    QPD 1 sum                                : -1.43319
    QPD 2 sum                                : -1.24641
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -1285[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -90[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2786
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.481597
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.65
    Slow locking signal sent to laser        : 0.543856
    Fast locking signal sent to laser        : 5.48801
    Calculated polarisation in cavity        : 97.7973
    Photodiode 1 after Wollaston prism       : 0.50656
    Photodiode 2 after Wollaston prism       : 45.4868
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2753.59
    Left Arm Q1 momentum                     : 3.66007
    Left Arm Q1 gauss meter                  : -0.23214
    Left Arm Q1 power supply polarity        : 0
    Left Arm Q2 power supply current         : 1575.86
    Left Arm Q2 momentum                     : 3.65968
    Left Arm Q2 gauss meter                  : 0.8273
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.34
    Left Arm D1 momentum                     : 3.66004
    Left Arm D1 NMR                          : 1.35576
    Left Arm Q3 power supply current         : 1457.11
    Left Arm Q3 momentum                     : 3.66
    Left Arm Q3 gauss meter                  : -0.73452
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.43
    Right Arm Q1 momentum                    : 2.62986
    Right Arm Q1 gauss meter                 : -0.04915
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1132.02
    Right Arm Q2 momentum                    : 2.63035
    Right Arm Q2 gauss meter                 : 0.592
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.493
    Right Arm D1 momentum                    : 2.62996
    Right Arm D1 NMR                         : 0.975945
    Right Arm Q3 power supply current        : 1046.67
    Right Arm Q3 momentum                    : 2.63043
    Right Arm Q3 gauss meter                 : 0.4683
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 9.89118
    Current on Unser monitor                 : 28.824
    Current on Upstream bcm                  : 9.66374
    Current on Downstream bcm                : 10.1186
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 10.1292
    Tiefenbach Hall A energy                 : 6067.38
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 2.05003
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.00663105
    IPM1C12.YPOS                             : 0.194641
    IPM1H04A.XPOS                            : -0.683415
    IPM1H04A.YPOS                            : -0.0384789
    IPM1H04B.XPOS                            : -0.668458
    IPM1H04B.YPOS                            : -0.0365459
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : 0.00131604
    Survey Y offset bpm12                     : 0.214906
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : Dummy
    Encoder position                         : 11801557
    fan frequency loop 1                     : 59.5
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.5
    temperature loop 1-2                     : 22.02
    temperature loop 1-3                     : 22.32
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.8717
    pressure fill bottle H2                  : 26.2043
    pressure ballast H2                      : 25.8564
    pressure exhaust H2                      : 24.7089
    cryogen input temp                       : 218.3
    crogen return flow                       : 0
     JT valve setting                        : -0.341797
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14151.log:
    
       Cumulative stats for 17894 events: 
       
       Events failing cut conditions:
       0         Low_beam  17894
       1        Beam_burp      4
       2          Evt_seq      0
       3         Pair_seq      1
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------