NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 15:04:27 on November 23, 2009
Entry number 302091
keyword=End_of_Parity_Run_14176__CODA_Config=Pvdis
************************************************
Run Number: 14176
End of Run Comment:
Run_type=Test,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=target boiling test, 100uA, raster size 6x6, fan speed 60Hz,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14176 at Mon Nov 23 15:04:21 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21184
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1723.07
Wien field : 49.796
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.538
Gun2: PC (PITA) NEG : 7.162
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75824
Pockels Cell Voltage NEG : 1.55067
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.155287
Photodiode on table : 387.338
Laser X position on QPD 1 : 110.057
Laser Y position on QPD 1 : 517.663
Laser X position on QPD 2 : 20.8653
Laser Y position on QPD 2 : -597.56
QPD 1 sum : -1.42465
QPD 2 sum : -1.25618
Position set point for adjustable
mirror 1 (either x or y) : -1285[c]
Position set point for adjustable
mirror 2 (either x or y) : -90[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.3079
Polarisation in cavity : LEFT
Reflection photodiode : 0.868583
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : 5.26827
Calculated polarisation in cavity : 16.4918
Photodiode 1 after Wollaston prism : 0.00714859
Photodiode 2 after Wollaston prism : 0.00512454
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 0.587472
Left Arm Q1 momentum : 2.65989e-05
Left Arm Q1 gauss meter : 0.0003191
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 0.0127439
Left Arm Q2 momentum : 0.00418122
Left Arm Q2 gauss meter : 0.0011026
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -0.00321344
Left Arm D1 momentum : 0.00319767
Left Arm D1 NMR : 1.58229
Left Arm Q3 power supply current : -0.00802337
Left Arm Q3 momentum : -1.87738e-05
Left Arm Q3 gauss meter : -0.00012983
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.00280488
Right Arm Q1 gauss meter : 3.29e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.0122569
Right Arm Q2 momentum : -2.94594e-05
Right Arm Q2 gauss meter : 0.0006046
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 1.88652
Right Arm D1 momentum : 0.101382
Right Arm D1 NMR : 0.879524
Right Arm Q3 power supply current : 0.10221
Right Arm Q3 momentum : 0.00251987
Right Arm Q3 gauss meter : 0.0001501
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.031593
Current on Unser monitor : 19.2578
Current on Upstream bcm : 0.0379391
Current on Downstream bcm : 0.0252469
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00544597
Tiefenbach Hall A energy : 6067.46
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 0.608864
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.64
temperature loop 1-2 : 22
temperature loop 1-3 : 22.31
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.5848
pressure fill bottle H2 : 25.9495
pressure ballast H2 : 25.8671
pressure exhaust H2 : 24.7181
cryogen input temp : 218
crogen return flow : 0
JT valve setting : -0.537109
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14176.log:
Cumulative stats for 99750 events:
Events failing cut conditions:
0 Low_beam 92743
1 Beam_burp 27
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------