NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 16:25:11 on November 23, 2009
Entry number 302103
keyword=End_of_Parity_Run_14178__CODA_Config=Pvdis
************************************************
Run Number: 14178
End of Run Comment:
Run_type=Cosmics,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14178 at Mon Nov 23 16:25:05 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21184
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1723.07
Wien field : 49.796
Laser attenuation Hall A : 70
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.538
Gun2: PC (PITA) NEG : 7.162
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.74847
Pockels Cell Voltage NEG : 1.54579
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.333627
Photodiode on table : 388.086
Laser X position on QPD 1 : 100.778
Laser Y position on QPD 1 : 519.633
Laser X position on QPD 2 : 24.2248
Laser Y position on QPD 2 : -597.839
QPD 1 sum : -1.40267
QPD 2 sum : -1.26106
Position set point for adjustable
mirror 1 (either x or y) : -1285[c]
Position set point for adjustable
mirror 2 (either x or y) : -90[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.0896
Polarisation in cavity : LEFT
Reflection photodiode : 0.868583
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.65
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -2.61674
Calculated polarisation in cavity : 60.227
Photodiode 1 after Wollaston prism : 0.0211245
Photodiode 2 after Wollaston prism : 0.00524371
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2754.28
Left Arm Q1 momentum : 3.661
Left Arm Q1 gauss meter : 0.23274
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1575.82
Left Arm Q2 momentum : 3.6596
Left Arm Q2 gauss meter : -0.8265
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1324.9
Left Arm D1 momentum : 3.6601
Left Arm D1 NMR : 1.35578
Left Arm Q3 power supply current : 1457.13
Left Arm Q3 momentum : 3.66004
Left Arm Q3 gauss meter : 0.73514
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 1977.59
Right Arm Q1 momentum : 2.62993
Right Arm Q1 gauss meter : 0.04923
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1131.73
Right Arm Q2 momentum : 2.6297
Right Arm Q2 gauss meter : -0.5926
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 402.972
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.44065
Right Arm Q3 power supply current : -0.00337762
Right Arm Q3 momentum : -8.48843e-06
Right Arm Q3 gauss meter : 0.0001061
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0336616
Current on Unser monitor : 20.1843
Current on Upstream bcm : 0.0418047
Current on Downstream bcm : 0.0255186
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.526472
Tiefenbach Hall A energy : 6067.46
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 2.99172
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.79
temperature loop 1-2 : 22
temperature loop 1-3 : 22.31
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.6428
pressure fill bottle H2 : 26.2074
pressure ballast H2 : 25.9632
pressure exhaust H2 : 24.7211
cryogen input temp : 218.2
crogen return flow : 0
JT valve setting : -0.634766
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
Did not obtain HAPPEX feedback cumulative results from
/adaqfs/halla/apar/feedback/runlog/ffb_14178.log