Log entry time 05:49:13 on November 24, 2009
Entry number 302299
keyword=End_of_Parity_Run_14192__CODA_Config=Pvdis
************************************************
Run Number: 14192
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=2 uA RHRS dipole going down,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=xxxx,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14192 at Tue Nov 24 05:49:05 EST 2009
CODA Configuration: Pvdis
# Timing board information: # Integrate Time = 33.00 ms, Ramp Delay = 0.00 us oversamp 1
Compton Run Number : 21201
-----------------------------------------
Wien angle : 74.7279
Wien BDL : 1723.07
Wien field : 49.796
Laser attenuation Hall A : 74
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) :
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5.2
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.5
Gun2: PC (PITA) NEG : 7.2
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 1.75824
Pockels Cell Voltage NEG : 1.54823
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr736mW
Calculated power in cavity : 670.539
Photodiode on table : 398.554
Laser X position on QPD 1 : 102.353
Laser Y position on QPD 1 : 522.147
Laser X position on QPD 2 : 25.4561
Laser Y position on QPD 2 : -604.144
QPD 1 sum : -1.42343
QPD 2 sum : -1.28182
Position set point for adjustable
mirror 1 (either x or y) : -1285[c]
Position set point for adjustable
mirror 2 (either x or y) : -90[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1491
Polarisation in cavity : RIGHT
Reflection photodiode : 0.499908
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.68
Slow locking signal sent to laser : 0.302142
Fast locking signal sent to laser : 5.06684
Calculated polarisation in cavity : 97.6559
Photodiode 1 after Wollaston prism : 52.3748
Photodiode 2 after Wollaston prism : 0.622643
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 2754.34
Left Arm Q1 momentum : 3.66107
Left Arm Q1 gauss meter : 0.23274
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1575.74
Left Arm Q2 momentum : 3.6594
Left Arm Q2 gauss meter : -0.8263
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 1324.85
Left Arm D1 momentum : 3.66007
Left Arm D1 NMR : 1.35577
Left Arm Q3 power supply current : 1457.03
Left Arm Q3 momentum : 3.65979
Left Arm Q3 gauss meter : 0.73511
Left Arm Q3 power supply polarity : enabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.00273065
Right Arm Q1 gauss meter : 3.15e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : -0.0115544
Right Arm Q2 momentum : -2.68477e-05
Right Arm Q2 gauss meter : -0.0012732
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 508.236
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.445169
Right Arm Q3 power supply current : 0.0943529
Right Arm Q3 momentum : 0.00248965
Right Arm Q3 gauss meter : 0.0001448
Right Arm Q3 power supply polarity : enabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 1.95587
Current on Unser monitor : 20.6159
Current on Upstream bcm : 1.89723
Current on Downstream bcm : 2.0145
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 2.15886
Tiefenbach Hall A energy : 6067.35
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : 2.6726
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 254.343
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0.003176
IPM1C12.YPOS : 0.201609
IPM1H04A.XPOS : -0.70923
IPM1H04A.YPOS : 0.0399813
IPM1H04B.XPOS : -0.687446
IPM1H04B.YPOS : 0.0261378
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0.003176
Survey Y offset bpm12 : 0.201609
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077688
fan frequency loop 1 : 59.5
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.31
temperature loop 1-2 : 21.98
temperature loop 1-3 : 22.29
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.6352
pressure fill bottle H2 : 26.0197
pressure ballast H2 : 25.095
pressure exhaust H2 : 25.362
cryogen input temp : 218.6
crogen return flow : 0
JT valve setting : -0.195312
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14192.log:
Cumulative stats for 99886 events:
Events failing cut conditions:
0 Low_beam 99886
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------