    User name apar

    Log entry time 20:06:09 on November 27, 2009

    Entry number 303090

    keyword=End_of_Parity_Run_14271__CODA_Config=Pvdis
    ************************************************
     Run Number: 14271
     End of Run Comment:
    
    Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=110 uA, Half wave plate OUT,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
    ************************************************
    End-of-Parity-run EPICS data for Run Number 14271 at Fri Nov 27 20:06:03 EST 2009
    CODA Configuration: Pvdis
    
    
    
    Compton Run Number                       : 21274
    -----------------------------------------
    Wien angle                               : 74.7279
    Wien BDL                                 : 1718.2
    Wien field                               : 49.796
    Laser attenuation Hall A                 : 150
    Laser power  Hall A                      : 100
    Beam Half-wave plate Set(off=out)        : OUT
    Beam Half-wave plate Read(off=out)       : OUT
    Rotating waveplate                       : 1200
    IA Cell Setpoint  Hall A                 : 4.79
    IA Cell Setpoint  Hall C                 : 4.87
    PZT X Setpoint  Hall A                   : 5.25
    PZT Y Setpoint  Hall A                   : 5
    PZT X Setpoint  Common                   : 4.9
    PZT Y Setpoint  Common                   : 5
    Gun2: PC (PITA) POS                      : 7.657
    Gun2: PC (PITA) NEG                      : 7.043
    Gun3: PC (PITA) POS                      : 5.0246
    Gun3: PC (PITA) NEG                      : 5
    Pockels Cell Voltage POS                 : 2.00733
    Pockels Cell Voltage NEG                 : 1.83394
    Helicity Clock Set                       : Free Clock
    Helicity Delay Set                       : 8 cycles
    Helicity Pattern Set                     : Quartet
    Helicity Clock Read                      : Free Clock
    Helicity Settle Read                     : 500
    Helicity Delay Read                      : 8 cycles
    Helicity Pattern Read                    : Quartet
    Helicity Frequency                       : 29.5596
    -----------------------------------------
    Compton stuffs
    -----------------------------------------
    Laser power                              : Pwr746mW
    Calculated power in cavity               : 0.562892
    Photodiode on table                      : 383.848
    Laser X position on QPD 1                : 93.4614
    Laser Y position on QPD 1                : 522.932
    Laser X position on QPD 2                : 24.3428
    Laser Y position on QPD 2                : -596.72
    QPD 1 sum                                : -1.41976
    QPD 2 sum                                : -1.25374
    Position set point for adjustable 
                   mirror 1 (either x or y)  : -3130[c]
    Position set point for adjustable 
                   mirror 2 (either x or y)  : -40[c]
    Laser minimum temperature (35.8)         : 35.8
    Laser temperature set point              : +47.2205
    Polarisation in cavity                   : LEFT
    Reflection photodiode                    : 0.825856
    Gain of locking servo                    : 135
    Tracking level (V) of locking servo      : 0.68
    Slow locking signal sent to laser        : 0.148324
    Fast locking signal sent to laser        : -1.09687
    Calculated polarisation in cavity        : 14.7066
    Photodiode 1 after Wollaston prism       : 0.0255154
    Photodiode 2 after Wollaston prism       : 0.0189727
    Step size for RHWP scan                  : 0
    Laser temp slow ramp (1 = on)            : ON
    Extent of laser temp slow ramp (C)       : 0.1
    Speed of laser temp slow ramp up         : 150
    Speed of laser temp slow ramp down       : 150
    -----------------------------------------
    Left Arm Magnets
    -----------------------------------------
    Left Arm Q1 power supply current         : 2754.28
    Left Arm Q1 momentum                     : 3.661
    Left Arm Q1 gauss meter                  : -0.23211
    Left Arm Q1 power supply polarity        : 1
    Left Arm Q2 power supply current         : 1576
    Left Arm Q2 momentum                     : 3.66
    Left Arm Q2 gauss meter                  : 0.8272
    Left Arm Q2 power supply polarity        : disabled
    Left Arm D1 power supply current         : 1325.02
    Left Arm D1 momentum                     : 3.66004
    Left Arm D1 NMR                          : 1.35576
    Left Arm Q3 power supply current         : 1457.2
    Left Arm Q3 momentum                     : 3.66021
    Left Arm Q3 gauss meter                  : -0.73447
    Left Arm Q3 power supply polarity        : disabled
    -----------------------------------------
    Right Arm Magnets
    -----------------------------------------
    Right Arm Q1 power supply current        : 1977.81
    Right Arm Q1 momentum                    : 2.63029
    Right Arm Q1 gauss meter                 : -0.04915
    Right Arm Q1 power supply polarity       : 1
    Right Arm Q2 power supply current        : 1131.72
    Right Arm Q2 momentum                    : 2.62966
    Right Arm Q2 gauss meter                 : 0.5918
    Right Arm Q2 power supply polarity       : enabled
    Right Arm D1 power supply current        : 931.559
    Right Arm D1 momentum                    : 2.62999
    Right Arm D1 NMR                         : 0.975959
    Right Arm Q3 power supply current        : 1046.46
    Right Arm Q3 momentum                    : 2.62991
    Right Arm Q3 gauss meter                 : 0.4682
    Right Arm Q3 power supply polarity       : disabled
    -----------------------------------------
    HallA & Injector BCMs and Energy
    -----------------------------------------
    Average current of the two cavities      : 109.091
    Current on Unser monitor                 : 126.688
    Current on Upstream bcm                  : 106.648
    Current on Downstream bcm                : 111.535
    Upstream Cavity Coefficient              : 42.6
    Downstream Cavity Coefficient            : 43.8
    Current on IBC0L02 (source)              : 109.779
    Tiefenbach Hall A energy                 : 6067.25
    Tiefenbach Hall C energy                 : 6070.48
    Delta(E)/E width (MV_AI_DXWID)           : 2.12203
    MBSY1c Hall A Beam energy                : 6081.48
    MBSY3c Hall C Beam energy                : 6090.49
    MBSY1c magnet current (amp)              : 254.343
    MBSY1c Bdl                               : 1.51764e+06
    -----------------------------------------
    ARC stuff and Raster
    -----------------------------------------
    Arc1 dp/p                                : 0
    Arc2 dp/p                                : 0
    Raster X width                                : 6
    Raster Y width                                : 6
    -----------------------------------------
    Target BPMs
    -----------------------------------------
    IPM1C12.XPOS                             : -0.04834
    IPM1C12.YPOS                             : 0.182557
    IPM1H04A.XPOS                            : -0.65159
    IPM1H04A.YPOS                            : 0.0446635
    IPM1H04B.XPOS                            : -0.654977
    IPM1H04B.YPOS                            : 0.0152779
    Survey X offset bpm4A                     : -0.63
    Survey Y offset bpm4A                     : -0.9
    Survey X offset bpm4B                     : 0.77
    Survey Y offset bpm4B                     : -1
    Survey X offset bpm12                     : -0.04834
    Survey Y offset bpm12                     : 0.182557
    Survey X HI SAT bpm12                     : 0
    Survey Y HI SAT bpm12                     : 0
    -----------------------------------------
    CRYO TARGET INFO
    -----------------------------------------
    Target                                   : L1 20cm
    Encoder position                         : 33077692
    fan frequency loop 1                     : 60
    fan frequency loop 2                     : 0
    fan frequency loop 3                     : 0
    temperature loop 1-1                     : 22.2
    temperature loop 1-2                     : 21.99
    temperature loop 1-3                     : 22.58
    temperature loop 2-1                     : 100.09
    temperature loop 2-2                     : 95.14
    temperature loop 2-3                     : 119.99
    temperature loop 3-1                     : 99.99
    temperature loop 3-2                     : 99.99
    temperature loop 3-3                     : 29.99
    pressure fill target H2                  : 25.4246
    pressure fill bottle H2                  : 25.7496
    pressure ballast H2                      : 25.7313
    pressure exhaust H2                      : 24.8844
    cryogen input temp                       : 218
    crogen return flow                       : 0
     JT valve setting                        : 0.195312
    -----------------------------------------
    Parameters used for HAPPEX feedback
    -----------------------------------------
    Parity DAQ Feedback Control (ON=1)        : 1
    HAPPEX Feedback results from 
     /adaqfs/halla/apar/feedback/runlog/ffb_14271.log:
    
       Cumulative stats for 99815 events: 
       
       Events failing cut conditions:
       0         Low_beam  13700
       1        Beam_burp    196
       2          Evt_seq      0
       3         Pair_seq      1
       4          Startup      1
       5       Low_beam_c      0
       
       
       --------------------------------------------------