    User name B. Quinn

    Log entry time 13:55:30 on November29,2009

    Entry number 303532

    keyword=Right-HRS magnet/cryo problems (tech)

    Right dipole queched (fault indicated on Lead A voltage and later on Helium level... helium level looked fine as dipole was crashing.)

    Soon afterwards, Q3 also went down with 'interlock.

    MCC called to tell us guard house got a cryo alarm from our hall...
    may have been a result of the crash, rather than the cause.

    For the moment, we don't intend to try to bring magnets back up on right side, even once liquid levels recover, since we can't run without Q1 anyway. There may be an independent problem to in dipole to fix tomorrow along with trouble-shooting Q1.