NEXT
Make New Entry,
Make Followup Entry
User name apar
Log entry time 15:54:38 on December 1, 2009
Entry number 303931
keyword=End_of_Parity_Run_14360__CODA_Config=Pvdis
************************************************
Run Number: 14360
End of Run Comment:
Run_type=Production,beam_energy=6.08,beam_polarization=87,beam_raster=on,comment_text=NO BEAM,dithering_magnet=on,dithering_magnets=,leftarm_p=3.66,leftarm_theta=12.9,parity_feedback=on,parity_ihwp=out,rightarm_p=2.63,rightarm_theta=20,target_fanspeed=60 Hz,target_type=20cm LD2
************************************************
End-of-Parity-run EPICS data for Run Number 14360 at Tue Dec 1 15:54:31 EST 2009
CODA Configuration: Pvdis
Compton Run Number : 21332
-----------------------------------------
Wien angle : 91.0422
Wien BDL : 2101.1
Wien field : 60.689
Laser attenuation Hall A : 85
Laser power Hall A : 100
Beam Half-wave plate Set(off=out) : OUT
Beam Half-wave plate Read(off=out) : OUT
Rotating waveplate : 1200
IA Cell Setpoint Hall A : 4.79
IA Cell Setpoint Hall C : 4.87
PZT X Setpoint Hall A : 5.25
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.659
Gun2: PC (PITA) NEG : 7.041
Gun3: PC (PITA) POS : 5.0246
Gun3: PC (PITA) NEG : 5
Pockels Cell Voltage POS : 2.00977
Pockels Cell Voltage NEG : 1.83883
Helicity Clock Set : Free Clock
Helicity Delay Set : 8 cycles
Helicity Pattern Set : Quartet
Helicity Clock Read : Free Clock
Helicity Settle Read : 500
Helicity Delay Read : 8 cycles
Helicity Pattern Read : Quartet
Helicity Frequency : 29.5596
-----------------------------------------
Compton stuffs
-----------------------------------------
Laser power : Pwr746mW
Calculated power in cavity : 0.168582
Photodiode on table : 390.08
Laser X position on QPD 1 : 88.6471
Laser Y position on QPD 1 : 533.212
Laser X position on QPD 2 : 32.2698
Laser Y position on QPD 2 : -606.918
QPD 1 sum : -1.28914
QPD 2 sum : -1.17805
Position set point for adjustable
mirror 1 (either x or y) : -3350[c]
Position set point for adjustable
mirror 2 (either x or y) : -420[c]
Laser minimum temperature (35.8) : 35.8
Laser temperature set point : +47.1139
Polarisation in cavity : RIGHT
Reflection photodiode : 0.852713
Gain of locking servo : 135
Tracking level (V) of locking servo : 0.68
Slow locking signal sent to laser : 0.148324
Fast locking signal sent to laser : -6.46219
Calculated polarisation in cavity : 17.3527
Photodiode 1 after Wollaston prism : 0.00781794
Photodiode 2 after Wollaston prism : 0.00519604
Step size for RHWP scan : 0
Laser temp slow ramp (1 = on) : ON
Extent of laser temp slow ramp (C) : 0.1
Speed of laser temp slow ramp up : 150
Speed of laser temp slow ramp down : 150
-----------------------------------------
Left Arm Magnets
-----------------------------------------
Left Arm Q1 power supply current : 190.661
Left Arm Q1 momentum : 0.253845
Left Arm Q1 gauss meter : -0.015915
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1575.91
Left Arm Q2 momentum : 3.6598
Left Arm Q2 gauss meter : 0.8274
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1325.21
Left Arm D1 momentum : 3.66009
Left Arm D1 NMR : 1.35578
Left Arm Q3 power supply current : 1456.99
Left Arm Q3 momentum : 3.65969
Left Arm Q3 gauss meter : -0.73452
Left Arm Q3 power supply polarity : disabled
-----------------------------------------
Right Arm Magnets
-----------------------------------------
Right Arm Q1 power supply current : 0.16022
Right Arm Q1 momentum : 0.00335101
Right Arm Q1 gauss meter : -8.32e-05
Right Arm Q1 power supply polarity : 1
Right Arm Q2 power supply current : 1132.04
Right Arm Q2 momentum : 2.6304
Right Arm Q2 gauss meter : 0.5921
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 931.825
Right Arm D1 momentum : 2.62994
Right Arm D1 NMR : 0.975939
Right Arm Q3 power supply current : 99.7189
Right Arm Q3 momentum : 0.25042
Right Arm Q3 gauss meter : 0.04444
Right Arm Q3 power supply polarity : disabled
-----------------------------------------
HallA & Injector BCMs and Energy
-----------------------------------------
Average current of the two cavities : 0.0332194
Current on Unser monitor : 17.7879
Current on Upstream bcm : 0.0405508
Current on Downstream bcm : 0.025888
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Current on IBC0L02 (source) : 0.00583681
Tiefenbach Hall A energy : 6067.46
Tiefenbach Hall C energy : 6070.48
Delta(E)/E width (MV_AI_DXWID) : -0
MBSY1c Hall A Beam energy : 6081.48
MBSY3c Hall C Beam energy : 6090.49
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.51764e+06
-----------------------------------------
ARC stuff and Raster
-----------------------------------------
Arc1 dp/p : 0
Arc2 dp/p : 0
Raster X width : 6
Raster Y width : 6
-----------------------------------------
Target BPMs
-----------------------------------------
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpm4A : -0.63
Survey Y offset bpm4A : -0.9
Survey X offset bpm4B : 0.77
Survey Y offset bpm4B : -1
Survey X offset bpm12 : 0
Survey Y offset bpm12 : 0
Survey X HI SAT bpm12 : 0
Survey Y HI SAT bpm12 : 0
-----------------------------------------
CRYO TARGET INFO
-----------------------------------------
Target : L1 20cm
Encoder position : 33077692
fan frequency loop 1 : 60
fan frequency loop 2 : 0
fan frequency loop 3 : 0
temperature loop 1-1 : 22.24
temperature loop 1-2 : 21.99
temperature loop 1-3 : 22.29
temperature loop 2-1 : 100.09
temperature loop 2-2 : 95.14
temperature loop 2-3 : 119.99
temperature loop 3-1 : 99.99
temperature loop 3-2 : 99.99
temperature loop 3-3 : 29.99
pressure fill target H2 : 25.0385
pressure fill bottle H2 : 25.5467
pressure ballast H2 : 25.1682
pressure exhaust H2 : 25.3651
cryogen input temp : 219.4
crogen return flow : 0
JT valve setting : -0.390625
-----------------------------------------
Parameters used for HAPPEX feedback
-----------------------------------------
Parity DAQ Feedback Control (ON=1) : 1
HAPPEX Feedback results from
/adaqfs/halla/apar/feedback/runlog/ffb_14360.log:
Cumulative stats for 99750 events:
Events failing cut conditions:
0 Low_beam 99750
1 Beam_burp 0
2 Evt_seq 0
3 Pair_seq 0
4 Startup 1
5 Low_beam_c 0
--------------------------------------------------